Problem Areas
1.15 Compass
1.15.1 Compass fails
Check:
Inspect the BtB connector of FPC Assembly Relay to Main
PBA.
Action:
1. If not properly connected – disconnect and reconnect it.
2. If dirty or oxidized – clean it.
3. If the BtB connector or FPC is damaged – replace FPC
Assembly Relay to Main PBA.
Check:
Inspect the compass chip on the FPC Assembly relay.
Action:
1. If the compass chip is damaged – replace the FPC
Assembly relay.
2. Replace Main PBA.