background image

Features

5

 

Side

Notes

• The LCD display unit has a built-in cooling fan. If 

“FAN ERROR (MEU)” or “FAN ERROR (LMD)” is 
displayed on the screen, turn the power off and consult 
with qualified Sony personnel.

• If a snowy picture appears when a computer signal is 

input, change a value of the vertical refresh rate.

• Changes in room temperature sometimes make the 

cabinet expand or contract, causing a noise. This 
does not indicate a malfunction.

• The LCD display unit is designed for use with 

MEU-WX2.

• Clean the rear cover area of the LCD display unit 

regularly.
Dust in the rear cover area may cause a problem 
with the cooling system of the LCD display unit.

• When the display unit is turned on at a low 

temperature, an approximately 1-hour warming-up 
period may be required to obtain stable brightness 
of the whole screen (for the LMD-212C only).

Features

The LMD-172WC is a 17-type, the LMD-232WC is a 
23-type and the LMD-322WC is a 32-type wide-screen 
LCD display unit, and the LMD-152C is a 15-type and 
the LMD-212C is a 21-type 4:3 LCD display unit.

High brightness LCD panel

Because of the display unit’s high brightness, high 
contrast, high speed response, and wide viewing angle  
technology, it can be used under various lighting 
conditions.

Rack mount display units (LMD-152C, 
LMD-172WC and LMD-212C only)

The LMD-152C/172WC/212C can be installed in a 
standard 19-inch rack using each optional Mounting 
Bracket MB-524, MB-522A or MB-523. This is 
essential when space is paramount in crowded OB 
vehicles.

Optional monitor stand with tilt function

The LMD-152C/172WC/232WC/212C can be installed 
on the optional SU-558 monitor stand, and the LMD-
322WC on the optional SU-559 floor stand. Thanks to 
the tilt and height adjustment functions of the SU-558 
monitor stand, the display screen height is adjustable to 
position with other equipment.

Lightweight, thin design

The lightweight, thin design reduces the load for an OB 
vehicle and the space needed for installation.

3-color tally lamp (except for the LMD-
322WC)

The tally lamp lights in red, green or amber to monitor 
each input picture and check the on-air mode.

1.2

Unit: cm

Summary of Contents for LMD-152C

Page 1: ...Operating Instructions 4 098 359 F3 1 LMD 152C LMD 172WC LMD 232WC 212C LMD 322WC 2005 Sony Corporation LCD Display Unit ...

Page 2: ...se You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital device pursuant to Subpart B of Part 15 of FCC Rules This device complies with Part 15 of the FCC Rules Operation is ...

Page 3: ...ion and Function of Parts and Controls 6 LMD 152C 172WC 232WC 212C 6 Front Bottom Panel 6 Rear Panel 6 LMD 322WC 6 Front Bottom Panel 6 Rear Panel 7 Connecting the AC Power Cord 7 Specifications 7 Dimensions i About this manual The instructions in this manual are for the following five models LMD 152C LMD 172WC LMD 232WC LMD 212C LMD 322WC Any differences in specifications are clearly indicated in...

Page 4: ...ction About the fluorescent tube A specially designed fluorescent tube is installed as the lighting apparatus for this unit If the LCD screen becomes dark unstable or does not turn on consult your Sony dealer Maintenance Before cleaning Be sure to disconnect the AC power cord from the AC outlet On cleaning the monitor screen The monitor screen surface is especially treated to reduce reflection of ...

Page 5: ... and the LMD 152C is a 15 type and the LMD 212C is a 21 type 4 3 LCD display unit High brightness LCD panel Because of the display unit s high brightness high contrast high speed response and wide viewing angle technology it can be used under various lighting conditions Rack mount display units LMD 152C LMD 172WC and LMD 212C only The LMD 152C 172WC 212C can be installed in a standard 19 inch rack...

Page 6: ... MEU WX2 Multiformat Engine Unit D DISPLAY SIGNAL IN connector DVI 1 0 compatible VGA XGA LMD 152C 212C or WXGA LMD 172WC 232WC signal can be input Note Be sure to turn off the power before connecting the cable Rear Panel A Stand mounting position For mounting the optional monitor stand SU 558 LMD 322WC Front Bottom Panel A POWER indicator The indicator lights in amber in power saving mode When th...

Page 7: ...70 000 LMD 172WC LCD Panel a Si TFT Active Matrix Picture size 17 type 364 218 424 mm W H Diagonal Resolution 1280 768 dots Pixel efficiency 99 99 Viewing angle 85 85 85 85 typical up down left right contrast 10 1 Aspect ratio 15 9 Colors 16 770 000 LMD 232WC LCD Panel a Si TFT Active Matrix Picture size 23 type 501 301 584 mm W H Diagonal Resolution 1280 768 dots Pixel efficiency 99 99 Viewing an...

Page 8: ... 20 to 30 C Humidity 30 to 80 No condensation Pressure 700 to 1 060 hPa Transport and storage conditions Temperature 10 to 40 C Humidity 0 to 80 Pressure 700 to 1 060 hPa Dimensions w h d LMD 152C Approx 379 297 70 mm LMD 172WC Approx 441 294 76 mm LMD 232WC Approx 563 372 78 mm LMD 212C Approx 515 409 81 mm LMD 322WC Approx 790 512 94 mm For details see Dimensions on pages i v Mass LMD 152C Appro...

Page 9: ...s i Dimensions LMD 152C Side Front Bottom Back with an ornamental cover Back without an ornamental cover Unit mm 250 173 9 75 3 378 9 148 4 148 4 272 6 2 6 52 2 76 2 4 M5 223 4 165 1 165 1 240 2 165 1 75 75 21 8 ...

Page 10: ...ions ii LMD 172WC Side Front Bottom Back with an ornamental cover Back without an ornamental cover Unit mm 250 3 180 1 81 5 441 4 144 2 149 8 270 9 2 6 52 2 76 2 4 M5 223 4 165 1 165 1 240 2 165 1 75 75 21 8 ...

Page 11: ...LMD 232WC Side Front Bottom Back with an ornamental cover Back without an ornamental cover Unit mm 250 3 180 7 82 6 563 4 185 9 185 9 273 6 2 6 52 2 76 2 223 4 240 2 240 2 165 1 165 1 165 1 165 1 4 M5 240 2 75 75 21 8 ...

Page 12: ...LMD 212C Side Front Bottom Back with an ornamental cover Back without an ornamental cover Unit mm 250 3 184 6 87 0 515 208 15 201 15 276 6 2 6 52 2 76 2 223 4 240 2 240 2 165 1 165 1 165 1 165 1 4 M5 240 2 75 75 21 3 ...

Page 13: ...Dimensions v LMD 322WC Side Top Front Bottom Back Unit mm ø11 3 2 94 108 790 254 4 257 4 330 2 M4 45 45 330 ...

Page 14: ......

Page 15: ......

Page 16: ...Printed on 100 recycled paper Printed in Japan Sony Corporation ...

Reviews: