– 14 –
KV-G14K3/G21K3
RM-870
3-2. CONVERGENCE
Preparations :
•
Before starting this adjustment, adjust the focus, horizontal size,
and vertical size.
•
Minimize the brightness setting.
•
Provide dot pattern.
(1)
Horizontal and Vertical Static Convergence
R G B
G
R
B
Center dot
V.STAT Magnet
BMC Magnet
1. (Moving horizontally), adjust the H.STAT magnet so that the
red, green and blue points are on top of each other at the center
of the screen.
2. (Moving vertically), adjust the V.STAT magnet so that the red,
green and blue points are on top of each other at the center of
the screen.
3. If the V.STAT Magnet cannot bring the red, green and blue points
together at the center of the screen, adjust the horizontal
convergence with the BMC Magnet and the V. STAT magnet in
the manner given below.
(In this case, the BMC Magnet and the V. STAT magnet
influence each other.)
4. If the V.STAT magnet is moved in the direction of the
a
and
b
arrows, the red, green and blue points move as shown below.
•
Operation of V.STAT Magnet.
B
R
B
R
a
b
b
b
a
b
a
b
a
R
G
B
b
B
G
R
b
b
a
a
1
2
3
G
G
B G R
R G B
•
Operation of BMC (Hexapole) Magnet.
b
a
b a
b a
a
b
a
b
R G B
R G B
b
a
R G
B
R G B
b
a
R G B
R G B
b
a
G B
R
R G B