– 31 –
KV-EF29N90
RM-882
SECTION 5
CIRCUIT ADJUSTMENTS
Entering service mode
With the unit on standby
↓
DISPLAY
↓
5
↓
VOL (+)
↓
POWER
The operation sequence puts the unit into service mode.
5-1. ADJUSTMENTS WITH COMMANDER
Service adjustments are made with the RM-882 that comes with
this unit.
1
,
4
Select the adjustment item.
↓
3
,
6
Raise/lower the data value.
↓
MUTING
Writes.
↓
0
Executes the writing.
7
,
0
All the data becomes the values in memory.
8
,
0
All user control goes to the standard state.
5
,
0
Service data initialization (Be sure not to use
usually.)
2
,
0
Write 50Hz adjustment data to 60Hz, or vice
versa.
The screen display is :
RM-882
Depends on the signals
PAL-N
: 50
NTSC, PAL-M : 60
00
VSH
1F
SERVICE
50
XXX
00 00 00
20
V2
1C
DATA
Mode
Adjstment item
Item number
SOFTWAR VERSION
H SYNC COUNTER
OEM CODE
1
2
3
4
5
6
7
8
0
9
MUTING DISPLAY GAME
POWER
MTS
VIDEO
TV
TV/VIDEO FREEZE
SWAP
PIP
DVD MENU
MENU
PIP CH
DYNAMIC
P.BASSO WAKE UP SLEEP VIRTUAL
DOLBY
VOL
CH
POWER
VIDEO
TITLE
Summary of Contents for KV-EF29N90
Page 58: ...MEMO KV EF29N90 RM 882 96 ...