– 29 –
2-9-3. PICTURE TUBE BRACKET ASSY REMOVAL
(KP-53S65C/61S65C)
• Disassemble HA board and speaker cord.
• Disassemble all the harness from purse lock.
3
Two screws
(Tapping screw 4X20)
4
Shield board
5
Eight screws
(Head tapping screw 4X20)
7
Two screws
(+BVTP 4X12)
8
X-RAY shield (L)
6
Picture tube
bracket assy
Cabinet assy
0
X-RAY shield (R)
9
Two screws
(+BVTP 4X12)
• except KP-61S65C
1
Three screws
(Head tapping screw 4X20)
2
Chassis assy
1) Remove
1
three screws (head tapping screw 4X20) and pull out
2
chassis assy from cabinet
assy.
2) Remove
3
two screws (tapping screw 4X20) and remove
4
shield board.
3) Remove
5
eight screws (head tapping screw 4X20) and release
6
picture tube bracket assy
from cabinet assy.
4) Remove
7
two screws (+BVTP 4X12) and remove
8
X-RAY shield (L).
5) Remove
9
two screws (+BVTP 4X12) and remove
0
X-RAY shield (R).
• except KP-61S65C
Summary of Contents for KP-41T65C