KDL-32BX355/40BX455/46BX455 9
SECTION 2 - TROUBLESHOOTING
2X Blink - Main Power Error
A loss of REG12V from the power supply triggers this protect event. The
usual cause is a failure of the main switching supply. In some instances,
excessive loading on the secondary supply lines can cause the switching
regulator to stop, or fail again, if a replacement board is installed.
3X Blink- DC Regulator/Audio Error
The REG 5V and D3.3V source originating on the Main Board is monitored
for low-voltage conditions by the CPU. A failure causing a 3X shutdown
requires replacing the Main Board.
4X Blink – Balancer Error
NOT USED IN THIS MODEL SERIES
The 4X error code is only used on models incorporating local dimming LED
backlighting. If a failure occurs on the LD board or one of the LED’s fails in
the panel the TV will shut down and display this diagnostic code. Models
using conventional non-local dimming LED backlighting do not utilize this
error code.
5X Blink - TCON Error/Panel Error
The 5X blink protection mode indicates a communications error with the
timing control circuits (TCON Board) has occurred. If the TCON Board is
available for replacement, replace it, if not, replace the LCD Panel Assembly.
In rare cases a loose or defective LVDS cable could also be the cause.
6X Blink - Backlight Converter System Failure
If the inverter circuits fails to generate high voltage or one or more of the
backlight lamps fails to light, the television will shut down and display this
diagnostics error. Observing for the presence of backlighting is crucial in
determining which component is likely at fault.
If the backlights turn on before the 6X shutdown occurs, it is safe to assume
that the inverter circuits are functioning and one of the lamps failed to ignite.
Replacing the LCD Panel assembly is necessary. If the backlights never
turn on before the 6X shutdown, the Inverter MT Board has failed. If this
board is available for replacement, replace it, if not, replace the LCD Panel
Assembly.
7X Blink - Temperature Failure
A digital thermometer IC located on the Main Board provides a temperature
reading of the chassis and LCD panel. If the temperature exceeds a pre-
determined point the TV will shut down. If this problem occurs immediately
at turn-on, the temperature sensing IC has failed and replacing the main
board is required. If this occurs after the TV has been running for a while,
check for ventilation issues that could cause the TV to run hotter than
normal.