KDF-46E3000/50E3000
KDF-46E3000/50E3000
27
Install Ballast Power in Clip on bottom of Duct Block.
Wire should be routed with RED tape in this position
Install Ballast Power to Clip and secure with Himelon
Tape 20 X 40. Tape should be centered between clips
Himelon Tape
Clips
Route 2P Thermal fuse
to clip and wire holder.
Route 3P Fan and 3P
[S] connector to clip on
top of Duct Blk.
191003657
HARNESS ASSY
Route HARNESS ASSY
191003657 to Clip on
Duct Block.
191003657
HARNESS ASSY
Connect 9P Ballast Control Connector and
2P Thermal Fuse Connector from
HARNESS ASSY 191003657
Secure Harness Assy, 2P Thermal fuse,4P [HAE], and 9P
Ballast control connector to wire holders as shown.
NOTE: Ensure 9P Connector is routed as shown
Wire Holders
Route 4P [HAE]
Connector through
Opening in Rear Cover
DUCT BLOCK ASSEMBLY (CONTINUED)