2-20
ILCE-6400/6400L/6400M
top side
rear side
5
screw (M1.7
u
4)
5
two screws (M1.7
u
4)
4
two screws (M1.7
u
5)
8
SY base block
3
glass assy flexible board.
2
charge unit flexible board.
6
Remove the SY base block.
aluminium elect cap
1
Peel off the tip of the ST insulating sheet
from the device unit.
7
Draw the contact unit flexible
board out of the inside of the
aluminium elect cap.
2-2-22. SY BASE BLOCK
SYS SET