ICD-P520/P530F
7
Sensitivity H
HOLD
ON
OFF
H
Sensitivity L
HOLD
L
To change the sensitivity again, press the [
x
STOP] button and
change the [HOLD] switch.
In a DSP Test mode, changing the mode and changing the sensitiv-
ity require the [
x
STOP] button be pressed.
5-5. USB Test
In this test, the ON/OFF status of VBUS is displayed and the SUS-
PEND test is performed.
The [
Nx
PLAY/STOP(ENTER)] button is pressed to display the
status of VBUS by “On” or “OFF” indication.
With the VBUS ON, the [HOLD] switch is operated (ON) to per-
form the SUSPEND test.
• VBUS Test
/Y
PLAY/STOP
(ENTER)
L
,
Y
STOP
with VBUS
without VBUS
• SUSPEND Test
With the VBUS ON, turn the [HOLD] switch ON to enter the SUS-
PEND mode.
When this mode is cancelled, the VBUS is turned OFF.
/Y
PLAY/STOP
(ENTER)
VBUS OFF
L
,
,
K
Y
STOP
Y
STOP
HOLD
ON
+
with VBUS
SUSPEND mode
5-6. RESET MENU
To enter the RESET MENU test, press the [DIVIDE] button.
When all of the buttons or controls located on the set are operated,
the system shows “Ok” if all of them are normally operated.
An operation of a switch is indicated by the number for verifi cation
in order to make a simple indication.
Note 1:
When 10 different operations of the switches are normally made
in any order (regardless of the order that pushbuttons are pressed
and the slide switch is set to ON and OFF), the system shows
“Ok”.
Note 2:
Clear memory when “ACCESS” is blinking on the display. (Do
this before “Ok” is shown.) To exit from this menu, the power has
to be turned off (battery to be removed).
Summary of Contents for ICD-P530F - Ic Recorder
Page 25: ...MEMO ICD P520 P530F 25 ...