6-59
HVR-M25J/M25U/M25N/M25E/M25P/M25C
1.
Playing Level Check
Mode
PLAY
Signal
Alignment tape: For audio check
(NTSC: XH5-3/PAL: XH5-3P)
Measurement Point
AUDIO OUT terminal (CH-1, 2)
Measuring instrument
Audio level meter
Oscilloscope
Specified Value
32 kHz mode section:
1 kHz signal must be outputted.
48 kHz mode section:
1 kHz signal level is
+8 to +12 dBs (NTSC)
+6 to +10 dBs (PAL)
44.1 kHz mode EMP ON section:
7.35 kHz signal level is
+2 to +6 dBs (NTSC)
0 to +4 dBs (PAL)
44.1 kHz mode EMP OFF section:
7.35 kHz signal level is
+8 to +12 dBs (NTSC)
+6 to +10 dBs (PAL)
Note:
Check that the data of page: 0, address: 10 is “00”.
Checking method:
1) Check that the play signal level satisfies the specified value.
2) Check with the oscilloscope that no clip is found in the output
waveform.
2.
Audio Test Signal Level Check
Mode
E-E
Signal
Audio test signal
Measurement Point
AUDIO OUT terminal (CH-1, 2)
Measuring instrument
Audio level meter
Oscilloscope
Specified Value
–11 to –8.5 dBs
Note 1:
0 dBs = 0.775 Vrms
Switch setting
1) COLOR BAR (IN/OUT REC menu) ................. ON [TONE]
Checking method:
1) Set the 60i/50i SEL (OTHERS menu) to “60i”.
2) Check that the output of AUDIO OUT terminal (CH-1, 2) sat-
isfies the specified value.
3) Check with the oscilloscope that no clip is found in the output
waveform.
4) Set the 60i/50i SEL (OTHERS menu) to “50i”.
5) Check that the output of AUDIO OUT terminal (CH-1, 2) sat-
isfies the specified value.
6) Check with the oscilloscope that no clip is found in the output
waveform.
7) Set the 60i/50i SEL (OTHERS menu) to “50i” or “60i”.
Note 2:
60i: HVR-M25J/M25U/M25N
50i: HVR-M25E/M25P/M25C