6-56
HVR-M25J/M25U/M25N/M25E/M25P/M25C
2.
V-COM Adjustment (PD-287 board)
Set the DC bias of the common electrode drive signal of LCD to
the specified value.
If deviated, the LCD display will be move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
47
Specified Value
The brightness difference between
the section-A and section-B is
minimum
Note 1:
Perform “LCD Automatic Adjustment” before this ad-
justment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
56
0D
Press PAUSE (Write) button.
3
C
47
Change the data so that
brightness of the section A
and section B is equal.
(The data should be “AB” to
“CD”)
4
C
47
Press PAUSE (Write) button.
5
C
56
C5
Press PAUSE (Write) button.
6
0
01
00
A
A
A
A
B
B
B
B
Fig. 6-2-13
3.
Transmissive Mode White Balance Adjustment
(PD-287 board)
Correct the white balance at transmissive mode.
If deviated, the LCD screen color cannot be reproduced.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
4B, 4C
Specified Value
LCD screen must not be colored
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD block
2. Light induction plate
3. IC6102
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
4B
8C
Press PAUSE (Write) button.
3
C
4C
77
Press PAUSE (Write) button.
4
Check that the LCD screen is
not colored. If not colored,
proceed to step 6.
5
C
4B
Change the data so that the
LCD screen is not colored.
(Note 3)
6
0
01
00
Note 3:
To write in the non-volatile memory (EEPROM), press
the PAUSE (Write) button each time to set the data.
4C