![Sony HKSP-1125 Installation Manual Download Page 16](http://html.mh-extra.com/html/sony/hksp-1125/hksp-1125_installation-manual_411098016.webp)
14 (E)
HKSP-1125
Item
Description
n
The HKSP-1125 operates as the following GPI specifications.
.
Pin assignment
Pin
Control
3 pin
LOW = REMOTE
HIGH = LOCAL (When LOCAL is selected, following pins
cannot be controlled by GPI too.)
5 pin
LOW = SQUEEZE
HIGH = Follows the setting of 8 pin.
8 pin
LOW = LETTER BOX
HIGH = EDGE CROP
.
Pin input TTL level
LOW
<
1.5 V
HIGH
>
3.5 V
V-SG
Starts up the VIDEO SG and selects the output signal.
\
OFF: Does not output the video signal. (The input video signal is processed and output directly.)
1:
Color Bars 100% (709)
2:
Color Bars 75% (709)
3:
Vertical Color Bars 100% (709)
4:
Vertical Color Bars 75% (709)
5:
Ramp
6:
Ramp with Chroma
7:
10 steps
8:
5 steps
9:
Cross Hatch
10:
Dot
11:
Box1
12:
Box2
13:
Vertical Ramp
14:
Vertical Ramp with Chroma
15:
100% White
16:
Gray
DIAG
Self diagnosis mode
\
OFF: Ends the self diagnosis mode.
ON:
Starts the self diagnosis mode.
n
The DIAG display blinks during self diagnosis mode, and when 60 seconds are left to the end of the self
diagnosis, the counts down starts. When the diagnosis is ended, lights up the DIAG display.
If the error is not existed, E-OK is displayed on the lower display.
If the error is existed, error number is displayed on the lower display.
n
For details of the diagnosis results, refer to Section “6-2. Self Diagnosis Mode Error Code List”.
m
When the EXIT key is pressed during DIAG, the diagnosis operation is interrupted and ended.
.
The display during DIAG is controlled normally.
.
The DIAG operation takes about one minute from a start to an end.
SOFT
Displays the version of CPU software on the lower display.
n
There is no hierarchy in this menu. Therefore, even if the dial is pressed, an item does not change.
PLD1
Displays the version of PLD mounted on the main board on the lower display.
n
There is no hierarchy in this menu. Therefore, even if the dial is pressed, an item does not change.
PLD2
Displays the version of PLD mounted on the connector board on the lower display.
n
There is no hierarchy in this menu. Therefore, even if the dial is pressed, an item does not change.
Summary of Contents for HKSP-1125