1-2. Supplied Accessories
Operation manual CD-ROM (PDF) .................................. 1
Installation manual ............................................................ 1
1-3. Operating Conditions
c
Good air circulation is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature: 5
d
C to 40
d
C
Operating humidity:
25 % to 80 % (non-condensing)
Storage temperature:
_
20
d
C to 60
d
C
Locations to avoid:
.
Areas where the unit will be exposed to direct sunlight
of any other strong lights.
.
Areas near heat sources.
.
Dusty areas or areas subject to vibration.
.
Areas with strong magnetic field.
.
Areas with much electrical noise.
.
Areas with much static electricity.
.
Areas that is impossible to find a specified room for
installation. (Refer to “1-5. Installation Space”.)
.
Areas windtight.
Tilt allowance:
Within 30
d
(Do not slant the front
and rear of the unit more than 30
d
.)
c
Fix the unit securely to avoid drop when the unit is operat-
ed at not-horizontal place.
1-1. Installation Procedure
Installation procedure of this unit is shown on the follow-
ing flowchart.
Refer to each section about detail of each flow.
The operation manual is also required to do
*
-marked
flow.
1-3. Operating Conditions
1-4. Power Supply
1-5. Installation Space
1-6. Rack Mounting
1-7. Matching Connectors and
Cables
1-8. Signal Inputs and Outputs
1-9. Switch Settings on Connector
Panel
1-10. Switch Settings on Circuit
Boards
1-11. System Setting
1-12. Opening/Closing the Lower
Control Panel
1-13. Reference System
1-14. Settings when Editor is
Connected
Start
Determination of
installation place
Unpacking
Rack mounting
*Connection
*Initial setup
*Operation check
End
n
If an error message appears on the time data
display area, refer to the operation manual.
(For more details, refer to the maintenance
manual volume 1.)
n
When the unit is transported, it is required to
pack the unit into the specified new packing
materials.
Do not reuse the packing materials.