HCD-SHAKE5/SHAKE6D
12
SECTION 3
TEST MODE
[PANEL TEST MODE]
This mode is used to check the fl uorescent indicator tube, LEDs,
keys, [VOLUME] jog, model, destination and software version.
Procedure:
1. Press [ENTER] button and [MUSIC] button simultaneously
and hold 3 seconds.
2. All LEDs and segments in fl uorescent indicator tube are lighted
up. All RGB LEDs are lighted up in white color.
3. When you want to enter to the software version display mode,
press [
+ /
] (SHAKE5) / [
+/] (SHAKE6D)
button.
** If display shown information below, please proceed
with [MODEL & DEST WRITE MODE] to write model &
destination.
•
“STORM-JR(T)” is shown for SHAKE-5.
•
“STORM-JRD(T)” is shown for SHAKE-6D.
The model information appears on the fl uorescent indicator
tube.
•
“STORM-JR” is shown for SHAKE-5.
•
“STORM-JRD” is shown for SHAKE-6D.
Press
[
+ /
] (SHAKE5) / [
+/] (SHAKE6D)
button again to view the destination information.
4. During the destination information display, press [
+ /
]
(SHAKE5) / [
+/] (SHAKE6D) button. Each time
[
+ /
] (SHAKE5) / [
+/] (SHAKE6D) button
is pressed, the fl uorescent indicator tube shows the version of
each category software in the following sequence: SC, MTK,
OPU, UI, PF, SYS, CD, CDMA, CDMB, ST, TA, TAS, TM,
BTM, BT, NFC and return back to model information display.
5. When
[
] button is pressed while the version numbers are
being displayed except model and destination, the date of the
software creation appears. When [
] button is pressed again,
the display returns to the software version display.
6. Press [
‒
/
] (SHAKE5) / [
‒
/PRESET
‒
] (SHAKE6D)
button, the key check mode is activated.
7. In the key check mode, the fluorescent indicator tube displays
“K 0 V0”.
Each time a button is pressed, “K” value increases. However,
once a button has been pressed, it is no longer taken into
account.
“V” value increases in the manner of 0, 1, 2, 3... if [VOLUME]
knob is turned clockwise, or it decreases in the manner of 0, 9,
8, 7... if [VOLUME] knob is turned counterclockwise.
8. When [ENTER] button is pressed after all LEDs and segments
in fl uorescent indicator tube light up, alternate segments in
fl uorescent indicator tube and LEDs would light up, all RGB
LEDs would light up in red color. If you press [ENTER]
button again, another half of alternate segments in fl uorescent
indicator tube and LEDs would light up, all RGB LEDs
would light up in green color. Pressing [ENTER] button again
would cause all segments in fl uorescent indicator tube and
LEDs light up, all RGB LEDs would light up in blue color.
Pressing [ENTER] button again would turn off all segments in
fl uorescent indicator tube and all LEDs including RGB LEDs.
9. To release from this mode, press the buttons in the same
manner as step 1, or disconnect the power cord.
[USER RESET]
The user reset clears all data including preset data stored in the data
fl ash to initial conditions exclude history mode data.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press
[
] button and [LED COLOR] button simultaneously
for 3 seconds.
3. “RESET” appears on the fl uorescent indicator tube. After that,
the fl uorescent indicator tube becomes blank for a while, and
the system is reset.
[COLD RESET]
The cold reset clears all data including preset data stored in the
data fl ash to initial conditions included history mode data. Execute
this mode when returning the set to the customer.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Press
[
] button and [AUDIO IN] button simultaneously for 3
seconds.
3. “COLD RESET” appears on the fl uorescent indicator tube.
After that, the fl uorescent indicator tube becomes blank for a
while, and the system is reset.
[CD/DVD SHIP MODE (WITH MEMORY CLEAR)]
This mode moves the optical pick-up to the position durable to
vibration and clears all data including preset data stored in the data
fl ash to initial conditions during the next AC-In. Use this mode
when returning the set to the customer after repair.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select CD (SHAKE5) / DVD/CD (SHAKE6D) function.
3. Press [CD] (SHAKE5) / [DVD/CD] (SHAKE6D) button and
[SOUND FLASH] button simultaneously for 3 seconds. The
system turns off automatically.
4. A message “MECHA LOCK” is displayed on the fl uorescent
indicator tube and the CD ship mode is set.
[CD/DVD TRAY LOCK MODE]
This mode let you lock the disc tray. When this mode is activated,
the disc tray will not open when [
Z
OPEN/CLOSE] button
is pressed. The message “LOCKED” will be displayed on the
fl uorescent indicator tube. This mode only applied when there is
disc(s) on the tray.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select CD (SHAKE5) / DVD/CD (SHAKE6D) function.
3. Press
[
] button and [OPTIONS] (SHAKE5) / [
X
] (SHAKE6D)
button simultaneously and hold down until “LOCKED” or
“UNLOCKED” displayed on the fl uorescent indicator tube
(around 5 seconds).
[CDM AGING MODE]
This mode is used for CDM aging.
Procedure:
1. Press
[
\/1
] button to turn on the system.
2. Select CD (SHAKE5) / DVD/CD (SHAKE6D) function.
3. Open the disc tray, insert a disc and close the tray.
4. Press [CD] (SHAKE5) / [DVD/CD] (SHAKE6D) button and
[MOVIE/GAME] button simultaneously for 3 seconds.
5. The fl uorescent indicator tube displays Aging Display “AG
xxxx/yyyy”.
“xxxx” represents the error counter
(Maximum Value of “xxxx” = 9999)
“yyyy” represents the cycle counter
(Maximum Value of “yyyy” = 9999)
6. Press
[
+ /
] (SHAKE5) / [
+/] (SHAKE6D) or
[
‒
/
] (SHAKE5) / [
‒
/PRESET
‒
] (SHAKE6D) to search
for Aging History Error Display
The
fl uorescent indicator tube displays “Mx E1E2E3E4”.
x: error history number
E1: Loading sequence JCP high
E2: Loading sequence JCP low
E3: Loading operation JCP
E4: Cam position operation JCP
7. Press [ENTER] to Aging Display
To release from CDM Aging Mode.
To release from this mode, press [
\/1
] button or perform COLD
RESET operation.
Summary of Contents for HCD-SHAKE5