2-8
VC-265
Adjustment remote
commander (RM-95)
Control switch block
(PS-1770) (8P)
Control switch block (FK-1770)
(A-7096-840-A) (51P)
When exiting the “Forced Camera Power ON” mode,
connect the control switch block (PS-1770) to the
control switch block (FK-1770).
Lens-EVF section
(Note)
VC-265 board (PC9/PC9E)
VC-265A board (PC6E)
CF-085 board (88P)
Mechanism deck
AC IN
AC power
adaptor
DC-IN connector
[SERVICE POSITION TO CHECK THE CAMERA SECTION]
Connection to Check the Camera Section
To check the camera section, set the camera to the “Forced camera power ON” mode. (Or, connect the control switch block
(PS-1770) to the control switch block (FK-1770) and set the power switch to the “CAMERA” position.)
Operate the camera functions of the zoom and focus using the adjustment remote commander (with the HOLD switch set in
the OFF position).
(Note) : The control switch block (FK-1770) is used for the repair parts as a jig.
Setting the “Forced Camera Power ON” mode
1) Select page: O, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01 and
press the PAUSE button of the adjustment remote
commander.
Exiting the “Forced Camera Power ON” mode
1) Select page: O, address: 01, and set data: 01.
2) Select page: D, address: 10, data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page : 0, address: 01, and set data: 00.
BJ-002 board (PC9/PC9E)
BJ-002A board (PC6E)
(60P)