5-48
11. REC C Current Adjustment (VC-195 board)
Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noises will increase and white modulation noises
will be produced.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin
!º
of CN910 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
65
Specified Value
Hi8 model :
A = 35.7
±
1.3mV (PAL)
Standard8 model :
A = 30.9
±
1.1mV (NTSC)
A = 30.0
±
1.1mV (PAL)
Note 1:
PAL Hi8 model:
CCD-TR840E/TR845E
NTSC Standard8 model: CCD-TR311
PAL Standard8 model: CCD-TR311E/TR411E/
TR412E/TR511E/TR512E/
TR640E/TR730E
Connection:
1) Remove C085 (0.01
µ
F, Pin
!§
of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-162-
970-11 CERAMIC CHIP 0.01
µ
F 10% 25V).
2) Connect Pin
1
of IC001 and GND with a 0.01F capacitor.
0.01
µ
F capacitor: 1-101-004-00
Preparations only for the model without REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “3. Bit value discrimination” of
“3-1-8. Service Mode”).
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to “0”.
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin
6
of CN935 of DD-105 board
and GND with 4.7k
Ω
resistor for a second.)
4.7k
Ω
resistor : 1-249-425-11
Adjusting method:
1) Insert a tape, set to recording mode.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
4) Select page: 2, address: 61, and set data: 30.
5) Select page: F, address: 65, change the data and set the REC
chroma signal level (A) to the specified value.
6) Press the PAUSE button of the adjusting remote commander.
7) Select page: 2, address: 61, and set data: 10.
8) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
9) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment: only for the model without
REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-16.
A
1.35
µ
sec
Center of the luminance line width
Summary of Contents for Handycam CCD-TR311
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......