5-20
GV-D1000/D1000E
5. PLL f
0
& LPF f
0
Fine Adjustment (VC-275 board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes to
“00” with in 5 sec. (Note1)
4
3
03
Check that the data is “00”.
(Note2)
5
0
01
00
Set the data.
Note1:
If it isn’t satisfied, there are errors.
Note2:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit value
discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
adjustment is defective
bit 6 = 1
LPF f
0
adjustment is defective
4-4. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
2
30
00
Set the data.
2
3
33
00
Set the data.
3
0
01
00
Set the data.
Summary of Contents for GV-D1000E - Digital Video Cassette Recorder
Page 55: ...Schematic diagram of the MS 95 board are not shown Pages from 4 43 to 4 52 are not shown ...
Page 66: ...Printed wiring board of the MS 95 board are not shown Pages from 4 71 to 4 72 are not shown ...
Page 70: ...Waveforms of the MS 95 board are not shown Page 4 76 is not shown ...
Page 74: ...Mounted parts location of the MS 95 board is not shown Page 4 80 is not shown ...
Page 75: ...5 1 GV D1000 D1000E SECTION 5 ADJUSTMENTS COVER COVER ...