4-93
•
MA-324 BOARD IC401 MB90096PF-G-150-BND (ON SCREEN DISPLAY CONTROLLER)
Pin No.
Pin Name
I/O
Function
1
CPOUT
O
Horizontal sync phase comparison result output terminal Not used (open)
2
AVSS1
—
Ground terminal (for internal VCO)
3
VCOIN
I
Internal VCO voltage input terminal Not used (fixed at “L”)
4
AVSS2
—
Ground terminal (for internal VCO)
5
RESET
I
System reset signal input from the system controller (IC501) “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
6
TEST
I
Input terminal for the test Not used (fixed at “H”)
7
VSS
—
Ground terminal
8
DOCKI
I
Dot clock signal input from the PLL (IC302)
9
DOCKO
O
Dot clock signal output terminal Not used (open)
10
FH
O
Output terminal of horizontal sync signal generated in PLL circuit Not used (open)
11
EVEN
I
Field control signal input terminal Not used (fixed at “H”)
12
HSYNC
I
Horizontal sync signal input from the LCD timing generator (IC301)
Based in this signal period, dot clock signal is generated Active level is programmable
13
VSYNC
I
Vertical sync signal input from the LCD timing generator (IC301)
Active level is programmable
14
DISP
I
Display outputs (ROUT, GOUT, BOUT, IOUT, VOB1, VOB2) control signal input from the
system controller (IC501)
15
VOB2
O
Semi-transparent period output terminal Active level is programmable Not used (open)
16
VOB1
O
OSD display period output terminal Active level is programmable
17
IOUT (C3)
O
Color signal (I) output terminal Active level is programmable Not used (open)
18
GOUT (C2)
O
Color signal (G) output terminal Active level is programmable
19
ROUT (C1)
O
Color signal (R) output terminal Active level is programmable
20
BOUT (C0)
O
Color signal (B) output terminal Active level is programmable
21
V3V
—
Coupling capacitor connection terminal
22
VCC
—
Power supply terminal (+5V)
23
TRE
O
Output of signal indicating that the command is being transferred to system controller (IC501)
and the fill operation is under way “H” active
24
SCLK
I
Serial data transfer clock signal input from the system controller (IC501)
25
SIN
I
Serial data input from the system controller (IC501)
26
CS
I
Chip select signal input from the system controller (IC501) “L” active
27
AVCC
—
Power supply terminal (+5V) (for internal VCO)
28
AV3V
—
Coupling capacitor connection terminal