17
KDL-40V4100/40V4150
KDL-40V4100/40V4150
1
2
LCD Panel
Balancer
(ETC- Inverter MT) Board
Balancer (ETC- Inverter MT) Board
Inverter Board Cover
WARNING
NEVER REMOVE THE
SCREWS SECURING THE
PLASTIC STRIP HOLDING
THE LAMP SOCKETS
DAMAGE TO THE
BACKLIGHT TUBES WILL
!
OCCUR!
1-9. BALANCER (ETC- INVERTER MT) BOARD REMOVAL
1 Remove 8 screws
2 Pull out the Board from the Lamp Socket
SHIELD REMOVAL
BALANCER (ETC-INVERTER) BOARD REMOVAL
WARNING
NEVER REMOVE THE
SCREWS SECURING THE
PLASTIC STRIP HOLDING
THE LAMP SOCKETS
DAMAGE TO THE
BACKLIGHT TUBES WILL
Only remove the screws securing the inverter
cover which may be metal or plastic. The
remaining plastic strip contains sockets for the
fluorescent backlights and should never be
loosened. The backlights will pop out of the
sockets and/or break the backlight requiring a
LCD panel replacement.
REMOVE SCREWS
SECURING
SHIELD
REMOVE
CONNECTORS AND
PULL BOARD TO
THE RIGHT
!
.
OCCUR!
BACKLIGHT
END VIEW
SOCKET
NOTE: The LVDS cable can only be installed one way. There is colored tape on the cable to determine which side is attached
to the TCON and which side is attached to the BU Board. Refer to Wire Dressing Illustration “Installation Procedure”
on
Page
33.