22
Basic Functions
Vibration Specifications
Test Method (Random vibration)
Fix the camera at the four fixation points of the base
using M2 screws.
Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
The camera vibration specification is to have no
malfunction after this test.
Power spectrum density 5 Hz to 50 Hz
4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 Hz to 100 Hz –36 dB/oct
Effective overall value
14.3 m/s
2
{1.46 G}
Test time
20 minutes
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.
4.67 (3/16)
ø26.312 (11/16)
ø25.2 (1)
ø22.443 (29/32)
Spectral Sensitivity
Characteristics
(FCB-EX15E/P only)
Use the graph as a reference value. (We can not
guarantee these values.)
This data is measured when the IR cut filter is removed
and the characteristics of the lens and optical source
characteristics are ignored.