VIBRATIONAL SPECIFICATIONS
Test method (Random vibration)
• Fix the camera at the four fixation points of the base using M2 screws.
• Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each
direction.
• The camera vibrational specification is to have no malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz
4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz
–36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes