Command List
FCB-EH6500(GB) A-EEP-100-11(1)
Register Setting
The register settings are enabled when the power is
turned off and then back on again. After turning the
power back on again, verify that the mode settings have
been changed.
Register No.
Value
VISCA
Baud Rate
00
00
(Iinitial Setting)
9600 bps
01
19200 bps
02
38400 bps
03
115200 bps
Monitoring
Mode
72
01
(Iinitial Setting)
1080i/59.94
02
1080i/60
03
NTSC Analog Output
(Stop Digital Output)
04
1080i/50
05
PAL Analog Output
(Stop Digital Output)
06
1080p/29.97
07
1080p/30
08
1080p/25
09
720p/59.94
0A
720p/60
0B
Reserved
0C
720p/50
0D
Reserved
0E
720p/29.97
0F
720p/30
10
Reserved
11
720p/25
12
Reserved
13
1080p/59.94
14
1080p/50
15
1080p/60
LVDS Mode
74
00
(Iinitial Setting)
Single Output
01
Double Output
Zoom Limit
50
00-FF
(Iinitial Setting: 00)
Wide Limit
(0: Disabled)
51
00-FF
(Iinitial Setting: 00)
Tele Limit
(0: Disabled)
D-Zoom Max
52
00-EB
(Iinitial Setting: EB)
Max. digital
zoom ratio =
256 ÷ (256-Value)
“StableZoom”
53
00
(Iinitial Setting: 00)
Off
01
On
Temperature Reading Conversion Value
(Reference Value)
Reading Value
pq (hex)
Temperature
Conversion
Value (ºC)
FB
−8 to −2
00
−3 to +3
0A
7 to 13
14
17 to 23
1E
27 to 33
28
37 to 43
32
47 to 53
3C
57 to 63