39
Command List
VISCA Command Setting Values
Exposure Control (1/2)
NTSC (s)
PAL (s)
Shutter Speed
15
1/10000
1/10000
14
1/6000
1/6000
13
1/4000
1/3500
12
1/3000
1/2500
11
1/2000
1/1750
10
1/1500
1/1250
0F
1/1000
1/1000
0E
1/725
1/600
0D
1/500
1/425
0C
1/350
1/300
0B
1/250
1/215
0A
1/180
1/150
09
1/125
1/120
08
1/100
1/100
07
1/90
1/75
06
1/60
1/50
05
1/30
1/25
04
1/15
1/12
03
1/8
1/6
02
1/4
1/3
01
1/2
1/2
00
1/1
1/1
Iris
11
F1.4 (F1.35)
10
F1.6
0F
F2
0E
F2.4
0D
F2.8
0C
F3.4
0B
F4
0A
F4.8
09
F5.6
08
F6.8
07
F8
06
F9.6
05
F11
04
F14
03
F16
02
F19
01
F22
00
CLOSE
* Number in ( ) applies to EVI-D90N/P only.
Gain
0F
+28 dB
0E
+26 dB
0D
+24 dB
0C
+22 dB
0B
+20 dB
0A
+18 dB
09
+16 dB
08
+14 dB
07
+12 dB
06
+10 dB
05
+8 dB
04
+6 dB
03
+4 dB
02
+2 dB
01
0 dB
00
–3 dB
Gain Limit
0F
+28 dB
0E
+26 dB
0D
+24 dB
0C
+22 dB
0B
+20 dB
0A
+18 dB
09
+16 dB
08
+14 dB
07
+12 dB
06
+10 dB
05
+8 dB
04
+6 dB