28
Command List
VISCA Camera-Issued Messages
ACK/Completion Messages
Command Messages
Comments
ACK
z0 4y FF
(y:Socket No.)
Returned when the command is accepted.
Completion
z0 5y FF
(y:Socket No.)
Returned when the command has been executed.
z = Device a 8
Error Messages
Command Messages
Comments
Syntax Error
z0 60 02 FF
Returned when the command format is different or when a command with illegal
command parameters is accepted.
Command Buffer Full
z0 60 03 FF
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Command Canceled
z0 6y 04 FF
(y:Socket No.)
Returned when a command which is being executed in a socket specified by the
cancel command is canceled. The completion message for the command is not
returned.
No Socket
z0 6y 05 FF
(y:Socket No.)
Returned when no command is executed in a socket specified by the cancel
command, or when an invalid socket number is specified.
Command Not Executable
z0 6y 41 FF
(y:Execution command
Socket No. Inquiry
command:0)
Returned when a command cannot be executed due to current conditions. For
example, when commands controlling the focus manually are received during auto
focus.
z = Device a 8
Network Change Message
Command Message
Comments
Network Change
z0 38 FF
Issued when power is being routed to the camera, or when the VISCA device is
connected to or disconnected from the VISCA OUT connector.
z = Device a 8