![Sony E-mount SEL200600G Service Manual Download Page 30](http://html.mh-extra.com/html/sony/e-mount-sel200600g/e-mount-sel200600g_service-manual_394060030.webp)
2-27
SEL200600G
rear (mount) side
front (lens) side
3
Set the vertical slit tube assy
to the TELE position.
vertical slit tube assy
1
3 group assy
2
Paste in the center of the G10 mask.
rear (mount) side
front (lens) side
notch
notch
4
Align the marking to the position in the
figure and install the 3 group block.
marking
marking
vertical slit tube assy
(from rear (mount) side)
3 group block
(from rear (mount) side)
3 group block
5
three 3 group pieces
Note
1:
When replacing the 3 group
piece, choose parts that do not
cause backlash and confirm
that movement is smooth.
9
sub coma
Note
3:
When replacing the sub
coma, choose parts that
do not cause backlash and
confirm that movement is
smooth.
9
two sub comas
Note
3:
When replacing the sub
coma, choose parts that
do not cause backlash and
confirm that movement is
smooth.
7
3 group piece block
7
3 group piece block
7
3 group piece block
6
three 3rd coma shafts
Note
2:
When replacing the 3rd
coma
shaft, choose parts
that do not cause backlash
and confirm that movement
is
smooth.
8
tapping screw (1.7
u
9.0)
(
1P
8
tapping screw (1.7
u
9.0)
(
1P
8
tapping screw
(1.7
u
9.0)
(
1P
0
tapping screw
(1.7
u
3.5)
(
1P
0
tapping screw
(1.7
u
3.5)
(
1P
0
tapping screw (1.7
u
3.5)
(
1P
Note:
Assemble in the order indicated by the numbers assigned to the parts in the fi gures such as
1
.
2-3-2. 3 GROUP ASSY
SYS SET
2019/06/28 22:04:56 (GMT+09:00)