![Sony DSC-G1 - Cyber-shot Digital Camera Service Manual Download Page 6](http://html.mh-extra.com/html/sony/dsc-g1-cyber-shot-digital-camera/dsc-g1-cyber-shot-digital-camera_service-manual_392627006.webp)
1-2
DSC-G1_L2
ENGLISH
ENGLISH
Repaired
by:
Block
Function
Detailed
Code
E
6 1
0 0
-
Detected the focus initialize
error.
Retry turn the power on by the power switch.
If it does not recover, check the focus sensor
signal (pin
ea
of CN301 on the SY-153 board)
and check the focus drive signal (pin
qk
to
wa
of
CN301 on the SY-153 board) of lens block.
If the focus drive signal is abnormality, check or
replace the zoom/focus motor drive IC (IC301 on
the SY-153 board). If the focus sensor signal is
abnormality, replace the lens block.
E
6 1
1 0
-
Detected the zoom initialize
error.
Retry turn the power on by the power switch.
If it does not recover, check the zoom sensor
signal (pin
wk
of CN301 on the SY-153 board)
and check the zoom drive signal (pin
ws
to
wg
of
CN301 on the SY-153 board) of lens block.
If the zoom drive signal is abnormality, check or
replace the zoom/focus motor drive IC (IC301 on
the SY-153 board). If the zoom sensor signal is
abnormality, replace the lens block.
E
6 2
0 2
-
Abnormality of IC for
steadyshot.
Check or replace the IC for steadyshot (IC603 on
the SY-153 board).
E
6 2
1 0
-
Abnormality of IC for
steadyshot.
(Lens initializing failure)
Perform checking of the item E: 62: 11 and E: 62:
12, then check or replace the IC for steadyshot
(IC603 on the SY-153 board).
E
6 2
1 1
-
Lens overheating (PITCH).
Check the HALL element signal (PITCH)(pin
1
,
2
of CN301 on the SY-153 board) and drive
signal (PITCH) (pin
9
to
qs
of CN301 on the
SY-153 board) of optical image stabilizer, or
replace the lens block.
If they are OK, check PITCH angular velocity
sensor (SE601 on the SY-153 board) peripheral
circuits.
E
6 2
1 2
-
Lens overheating (YAW).
Check the HALL element signal (YAW)(pin
6
,
7
of CN301 on the SY-153 board) and drive
signal (YAW) (pin
qd
,
qj
of CN301 on the SY-
153 board) of optical image stabilizer, or replace
the lens block.
If they are OK, check YAW angular velocity
sensor (SE602 on the SY-153 board) peripheral
circuits.
E
6 2
2 0
-
Abnormality of thermistor.
Check the OIS temp sensor of optical image
stabilizer (pin
5
of CN301 on the SY-153
board).
E
9 1
0 1
(The flash icon
blinks at 3.2 Hz)
Abnormality when flash is
being charged.
Check or replace the flash unit.
Self-diagnosis Code
Message
Symptom/State
Correction