28
Power requirements
DC
+
5 V (
±
5%)
Power consumption
2 W (Max.)
Operating temperature range
0 to
+
45
°
C/32 to 113
°
F
Storage temperature range
−
10 to
+
50
°
C/14 to 122
°
F
Head cable length
10 m (PL22-AF, AU), 3 m (PL22-3F, 3U)
Total weight
PL22-AF, AU: 1030 g /2.318 lb
PL22-3F, 3U: 620 g / 1.395 lb
Accessories
Head installation screws (M4
×
20) ............... 2 pcs.
Detector installation screws (M4
×
10) .......... 4 pcs.
Cable clamp screws (M4
×
8) ........................ 3 pcs.
Technical Information .................................... 1 pc.
Output connector ........................................... 1 set
Instruction manual ......................................... 1 pc.
Cable clamps ............................................... 3 pcs.
Spacer ............................................................ 1 pc.
Signals PCA, PCB and ALARM or PCU, PCD and ALARM
Signals
*
PCA,
*
PCB and
*
ALARM or
*
PCU,
*
PCD and
*
ALARM
Output circuit
Voltage-differential drivers (SN75113) are used to
produce outputs. Therefore use voltage-differential
line receivers (SN75115 or equivalent) to receive
those outputs.