2-5
DCR-TRV60/TRV60E/TRV70
2-4. CABINET (R) BLOCK ASSEMBLY (2)
6
S
crew
(M1.7
×
4),
lock ace, p2
4
S
crew
(M1.7
×
4),
lock ace, p2
3
S
crew
(M1.7
×
4),
lock ace, p2
2
Screw
(M1.7
×
2.5),
lock ace, p2
Caution
Caution
9
FP-666 flexible
board (6P)
q;
FP-660 flexible
board (39P)
Caution : The power capacitor of the flash unit is charged up to 300 V maximum. If you touch
the capacitor terminal that is charged to high voltage, you will receive an electric
shock. This high voltage is not discharged even if you turned off the main power
of this set, and it residues. Discharge the residual voltage referring to the service
note (page 1-2).
1
Open the stroboscope block in the
direction of the arrow
A
.
7
Slide the eject knob in
the direction of the arrow
to release the lock.
When installing the FP-660
flexible board, fold it into the
shape as shown.
5
Open the LCD block in
the direction of the
arrow
B
.
8
Remove the cabinet
(R) in the direction of
the arrow
C
.
A
B
C
Caution :
HIGH VOLTAGE
DI-088 board
The FP-660 flexible board may be damaged
if you remove the cabinet (R) section forcibly.
Be very careful not to damage the flexible
board.
The FP-666 flexible board may be damaged
if you remove the cabinet (R) section forcibly.
Be very careful not to damage the flexible
board.
www.freeservicemanuals.info
Digitized in Heiloo Netherland