— 8 —
DCR-TRV130/TRV130E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
Page
5-13
Type M
:
Added portion.
1. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
38, 39, 3A
Specified Value 1
88 to 8C
Specified Value 2
15 to 19
0-1. Lens Type Input
Distinguish the type of the lens being used for the camcorder,
and input data corresponding to the type.
Subject
Not required
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
E
F
Adjustment Address
5C, 5D, 5E, 5F
2C
Note:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
65
Set the data, and press PAUSE button.
3
0
03
19
Set the data.
4
1
Check that the data.
When the data is “0000”, proceed
to step 5. (Glass lens type)
When the data is “0001”, proceed
to step 11. (Plastic lens type)
5
E
5C
21
Set the data, and press PAUSE button.
6
E
5D
84
Set the data, and press PAUSE button.
7
E
5E
FC
Set the data, and press PAUSE button.
8
E
5F
F7
Set the data, and press PAUSE button.
9
F
2C
D6
Set the data, and press PAUSE button.
10
Proceed to step 16.
11
E
5C
22
Set the data, and press PAUSE button.
12
E
5D
51
Set the data, and press PAUSE button.
13
E
5E
FD
Set the data, and press PAUSE button.
14
E
5F
C4
Set the data, and press PAUSE button.
15
F
2C
D7
Set the data, and press PAUSE button.
16
6
01
00
Set the data, and press PAUSE button.
17
0
03
00
Set the data.
18
0
01
00
Set the data.
0-2. CCD Imager Type Input (DCR-TRV130 (NTSC))
Distinguish the type of the CCD imager used for the camcorder,
and input data corresponding to the type.
Subject
Not required
Measurement Point
Display data of page 6 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
7
F
Adjustment Address
A2, A3
3B, DD DF, FB
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
04
Check that the data is “00” to “21”.
3
Check that the type of the CCD
imager.
When the CCD type M is used,
proceed to step 4.
When the CCD type S is used,
proceed to step 11.
4
7
A2
57
Set the data, and press PAUSE button.
5
7
A3
88
Set the data, and press PAUSE button.
6
F
3B
70
Set the data, and press PAUSE button.
7
F
DD
52
Set the data, and press PAUSE button.
8
F
DF
E0
Set the data, and press PAUSE button.
9
F
FB
81
Set the data, and press PAUSE button.
10
Proceed to step 17.
11
7
A2
00
Set the data, and press PAUSE button.
12
7
A3
00
Set the data, and press PAUSE button.
13
F
3B
4A
Set the data, and press PAUSE button.
14
F
DD
72
Set the data, and press PAUSE button.
15
F
DF
D0
Set the data, and press PAUSE button.
16
F
FB
01
Set the data, and press PAUSE button.
17
0
01
01
Set the data.
Summary of Contents for DCR-TRV130 - Digital8 Camcorder
Page 11: ...1 2 ...
Page 12: ...1 3 ...
Page 13: ...1 4 ...
Page 14: ...1 5 ...
Page 15: ...1 6 ...
Page 16: ...1 7 ...
Page 17: ...1 8 ...
Page 18: ...1 9 ...
Page 19: ...1 10 ...
Page 20: ...1 11 ...
Page 21: ...1 12 ...
Page 22: ...1 13 ...
Page 23: ...1 14 ...
Page 24: ...1 15 ...
Page 25: ...1 16 ...
Page 26: ...1 17 ...
Page 27: ...1 18 ...
Page 28: ...1 19 ...
Page 29: ...1 20 ...
Page 30: ...1 21 ...
Page 31: ...1 22 ...
Page 32: ...1 23 ...
Page 33: ...1 24 ...
Page 34: ...1 25 ...
Page 35: ...1 26 ...
Page 36: ...1 27 ...
Page 37: ...1 28 ...
Page 38: ...1 29E ...
Page 68: ...DCR TRV130 TRV130E 4 17 4 18 RGB TIMING GENERATOR BACK LIGHT PD 131 ...
Page 80: ...5 1 DCR TRV130 TRV130E SECTION 5 ADJUSTMENTS ...