2-16
DCR-IP210/IP210E/IP220/IP220E
VC-308 board
CD-406 board
CN1000
LD-112 board
AC power
adaptor
AC IN
Lens block assembly
LANC jack
ST-076 board
CN4201
Adjustment remote
commander (RM-95)
FP-542 flexible board
Cabinet (F) block assembly
Cabinet (L) block assembly
DC-IN connector
DC-098 board
DI-087 board, MS holder assembly
[DI-087 BOARD SERVICE POSITION]
When the Control switch block (PW-2980 or SS-2980) is removed, enter the equipment in the “Forced power ON” mode.
Setting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 01
(CAMERA mode) or set data: 02 (VTR mode),
and press the PAUSE button of the adjustment
remote commander.
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 00.
3) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remote commander.
4) Select page: 0, address: 01, and set data: 00.
CN451
CN001
CN463
CN2020
WWW.FREESERVICEMANUALS.INFO