Summary of Contents for DABK-3343HR

Page 1: ...DIGITAL AUDIO RECORDER PCM 3348HR CONVERTER BOARD PACK DABK 3343HR INSTALLATION MANUAL 1st Edition Revised 1 PCM 3348HR Serial No 10001 and Higher DABK 3343HR Serial No 10001 and Higher ...

Page 2: ... Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entretien Afin de réduire...

Page 3: ... 1 8 1 4 4 Height Adjustment of Remote Stand 1 8 1 4 5 Angle Adjustment of Remote Stand Top Plate 1 8 1 5 Installation of the DIO 43 Board Supplied 1 9 1 6 Using the Extension Board 1 10 1 6 1 Using Extension board EXT 310 1 10 1 6 2 Using Extension board EXT 309 1 11 1 7 Connector Cable 1 12 1 7 1 PCM 3348HR 1 12 1 7 2 RM 3348HR 1 13 1 8 Installation of the DABK 3343HR 1 14 1 9 Installation of th...

Page 4: ...ed for PCM 3348HR PCM 3348HR Operation Manual Supplied with the PCM 3348HR PCM 3348HR Quick Refernce Supplied with the PCM 3348HR These manuals describe the application and operation of the PCM 3348HR PCM 3348HR Maintenance Manual Volume 1 Not supplied with the PCM 3348HR This manual describes the detailed service information with the intention of servicing based on the component parts Service Ove...

Page 5: ...c fields Areas near heat sources Ventilation Radiation PCM 3348HR has the fan to cool the entire unit If the intake on the fan is blocked or the fan stops rotating the unit may be damaged Therefore there must be at least 20 cm of clearance at the rear of the nuit 1 2 Power Supply 1 2 1 AC Power Supply The power supplies of the PCM 3348HR RM 3348HR are shipped with the following power voltage setti...

Page 6: ...chrauben an der Halterung befestigt werden Wartung darf nur von qualifizierten Fachpersonal ausgeführt werden PCM 3348HR For UC Unit mm For CE Unit mm CAUTION For PCM 3348HR CE model only This model is High Leakage Current be sure to connect the wires by Field wiring This work may be regulated by laws of each country Follow laws of each country In addition when installation attach an AC inlet to a...

Page 7: ...3 1 PCM 3348HR 1 Dimensions 2 Working space 127 871 816 54 1420 269 323 358 Extension board EXT 310 Mecha deck Extention board EXT 309 RM DIO rack Connector panel Switching regulator 740 167 610 Unit mm Unit mm 916 1047 1 3 Installation Space ...

Page 8: ...348HR 1 3 2 RM 3348HR 1 Dimensions Remote control unit 2 When the remote control unit is installed to the remote stand 5 10 46 32 20 220 150 600 364 536 526 424 490 221 266 Unit mm Unit mm 1 3 Installation Space ...

Page 9: ...washer W8 2 Screw B4 x 8 1 Screw PSW4 x 14 4 Cord clamper 1 Procedure 1 Assembly of the Leg Assembly Attach the leg assembly to the support using the four screws M5 x 25 2 Installing the Slider Top Plate and Cord Clamper Install the slider top plate and cord clamper as shown in the figure below 1 4 Installing the Remote Control Unit on the Remote Stand Top plate M5 x 12 2pcs Knob bolt M8 x 20 2pcs...

Page 10: ...nter of the ring shaped hole of the remote stand top plate 2 Temporarily secure the remote unit to the top plate from the bottom of the top plate with four PSW4 x 16 screws When the screws cannot be inserted into the holes slide the remote unit slightly backward and forward or right and left to adjust the position When all the four screws has been inserted in the holes fasten them securely 3 Secur...

Page 11: ...rew B4 x 8 5 Secure the power cord with the cord clamp located at the bottom of the top plate 6 Secure the remote cable and the power cord with the cord clamp on the leg Assembled Unit 3 Lock 2 Insert the power cord 1 Insert the remote cable Cord clamper Leg assy 1 4 Installing the Remote Control Unit on the Remote Stand AC inlet Wire stopper Power cord B4 x 8 Plug holder Supplied 2Lock 1Insert th...

Page 12: ...le and power cord from the clamper 2 Loosen the remote stand height adjustment knob bolt and adjust the height of the slider To raise the top plate loosen the height adjustment knob bolt and pull up the top plate After adjusting its height tighten the height adjustment knob bolt to secure the top plate 3 Secure the remote cable and power cord with the cord clamper 1 4 5 Angle Adjustment of Remote ...

Page 13: ...e DIO 43 Board Supplied The DIO 43 board which is supplied with PCM 3348HR is used when replacing the DIO 46 board one of the boards being installed DIO 43 board Installation Slots n Turn the power of PCM 3348HR off befor removing or inserting boards Procedure 1 Loosen the two fixing screws right and left screws of the DIO 46 board Grasping the both handles of the DIO 46 board panel pull the board...

Page 14: ...ARP 5 MEM 68 ED 50 ED 40 ED 41 MT 128 CK 30 DAD 30 SV 163 SVD 15 n Turn the power of PCM 3348HR off before removing or inserting boards Procedure 1 Open the front door 2 Loosen the two screws of the board to be extended Release the upper and lower lock levers and pull the board out of the main unit in the direction of the arrow 3 After the board has been extracted insert the extension board EXT 31...

Page 15: ...rds Procedure 1 Loosen the two screws right and left screws of the board to be extended Grasping the both handles of the board panel pull the board out of the main unit in the direction of the arrow 2 After the board has been extracted insert the extension board EXT 309 in the direction of the arrow 3 Insert the board in the extension board EXT 309 connector in the direction of the arrow 1 6 Using...

Page 16: ...le 1 508 084 11 1 OUTPUT A1 A2 XLR 3P male XLR 3P female 1 508 083 11 2 TIME CODE INPUT XLR 3P female XLR 3P male 1 508 084 11 1 OUTPUT A1 A2 XLR 3P male XLR 3P female 1 508 083 11 2 SECTOR ADDRESS INPUT OUTPUT BNC BNC SECTOR SYNC INPUT OUTPUT WORD SYNC INPUT OUTPUT REFERENCE VIDEO INPUT METER D sub 37P female D sub 37P male 1 566 357 21 37 pin D sub CABLE 1 568 196 11 DIGITAL I O panel PCM 3348HR...

Page 17: ...ub 25P male D sub 25P female 1 563 817 21 REC RDY CONTROL 1 to 4 D sub 50P male D sub 50P female 1 563 819 11 1 CANNON XLR 3 12C or equivalent 2 CANNON XLR 3 11C or equivalent 3 Length 3m 10m 30m 4 Length 5m 10m 30m 1 7 2 RM 3348HR RM 3348HR connector Connectors Cables used at Name to be used Name Sony part number SECTOR ADDRESS IN OUT BNC BNC WORD SYNC IN OUT SECTOR SYNC IN OUT IEEE Std 488 1978 ...

Page 18: ...on of the DABK 3343HR 1 9 Installation of the Shield Panel For CE only 1 9 Installation of the Shield Panel For CE only Since the shield cover is attached to the PCM 3348HR CE model in order to satisfy the performance of unit under the heavy electromagnetic field When using the unit be sure to attach the shield cover in accordance with the following procedure Procedure 1 Load the tape 2 Attach the...

Page 19: ...ad Make sure that there is no residual cleaning fluid on the parts after cleaning Daily cleaning will prevent the buildup of oxidation on the tape 2 1 2 Magnetic erasing on the heads Bring the erasing surface of the magnetic eraser and the head as close as possible to each other and turn the power on for the magnetic eraser Slowly bring the magnetic eraser a sufficient distance from the head and t...

Page 20: ...iring potential defects before they occur The purpose of this periodical check and maintenance is satisfying the electrical and mechanical specifications mentioned in the operating instructions of PCM 3348HR 2 2 2 Periodic Inspections It is also recommended for long term trouble free opera tion that the unit be periodic inspections The periodic inspection items are showm in Table 1 Read the tape r...

Page 21: ...ch plunger 9 Check the function of the tape shifter 10 Check if there is irregular functional noise when a tape loading or unloading 11 Check the HBU alignment 1 Check the cleaner guides condition 2 Check the tape guides G1 to G3 condition 3 Check the azimuth of the SYNC PB head Check the head to tape contact of the SYNC PB head Check the height of the SYNC PB head 4 Check the azimuth of the REC h...

Page 22: ...heck the playback characteristics for digital audio track 4 Check the ARP recording and playback 5 Check the DAD characteristics 1 Measure the noise ratio 2 Measure the frequency characteristics 3 Measure the distortion rate Mechanical section 1 Punch in out functions 2 Function control system 3 Shuttle function 2 2 Periodic Inspections ...

Page 23: ... 5 25V Earth Ground The material contained in this manual consists of information that is the property of Sony Corporation and is intended solely for use by the purchasers of the equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described i...

Page 24: ...PCM 3348HR UC CE E 3 192 592 02 Printed in Japan Sony Corporation 1998 12 08 Broadcasting Professional Systems Company 1997 ...