— 8 —
SECTION 4
SERVICE MODE
Service Mode (service program)
The equipment is provided with a service program built in the
microcomputer, like conventional models.
Service program operation methods are described in the following.
• Step 1 (Service mode setting method)
1. Turn OFF the HOLD switch the external power supply discon-
nected (power is not applied to the set).
2. Solder across the T802 (TEST) terminals (pin
%¢
, IC801 (TEST)
is grounded).
3. Connect an external power supply.
Thus, the set is switched to the service mode.
• Step 2 (Operation in the service mode )
1. Once the service mode is effected, the LCD displays 5 indica-
tions each of which is repeatedly displayed.
However, the following operations can be activated even if LCD
indication is effected.
2. By pressing the
+
or
=
key, the optical pick-up movable
inwardly or outwardly. However, if this is activated, tracking
servo and sled servo are turned OFF, so it can be turned ON by
pressing the PLAY MODE key, if required.
3. By pressing the REPEAT/ENTER key, the tracking gain-up
mode becomes active.
4. By pressing the
^
key, focus is turned ON from focus search-
ing while entering CLV-S (pull-in mode).
Without disc, focus searching is repeated continuously.
5. By pressing the PLAY MODE key, tracking servo, sled servo
and CLV-A (servo in PLAY) are turned ON.
6. When 4. and 5. are performed, playing begins. No muting is
ON in the service mode.
7. By pressing the
p
key, all servos (focus tracking and sled) are
turned OFF. However, the disc motor revolves for a while by
inertia.
• Step 3 (Resetting service mode )
1. Be sure to disconnect the external power supply and remove
the solder bridge at the TEST terminals connected in setting.
2. The set thus becomes available for normal operation.
– MAIN BOARD – (Side A)
IC801
T802
(TEST)
T802 (TEST)
Normal mode: Open
Test mode: Short
^
p
^
(PLAY/PAUSE)
p
(STOP)
FOCUS is turned ON
to effect pull in mode
Tracking servo and sled
servo are turned ON
[All servos are turned OFF]
PLAY MODE
HOLD OFF
→
ON
[Be sure to turn OFF the HOLD switch]
(if ON, pressing each key is deactivated)
REPEAT/ENTER
Tracking gain-up mode while pressing
+
(FF)
The optical pick-up
is moved outwardly
=
(FR)
The optical pick-up
is moved inwardly
Fig.4 Location of test terminal
Fig.3 Layout of each key