6-3. SCHEMATIC DIAGRAM — CD SECTION —
— 21 —
— 22 —
— 23 —
— 24 —
— 25 —
Note on Schematic Diagram:
• All capacitors are in µF unless otherwise noted. pF: µµF
50 WV or less are not indicated except for electrolytics
and tantalums.
• All resistors are in
Ω
and
1
/
4
W or less unless otherwise
specified.
•
¢
: internal component.
•
C
: panel designation.
•
U
: B+ Line.
•
H
: adjustment for repair.
• Power voltage is dc 3V and fed with regulated dc power
supply from external power voltage jack.
• Voltages and waveforms are dc with respect to ground in
service mode.
no mark : CD PLAY OR COMMON
(
) : FM
<
> : AM
• Voltages are taken with a VOM (Input impedance 10 M
Ω
).
Voltage variations may be noted due to normal production
tolerances.
• Waveforms are taken with a oscilloscope.
Voltage variations may be noted due to normal production
tolerances.
• Circled numbers refer to waveforms.
• Signal path.
F
: FM
f
: AM
J
: CD
• Abbreviation
E13
: AC 220 – 230V area model
E33
: AC 100 – 240V area model
E92
: Central & South American
Note:
The components identi-
fied by mark
!
or dotted
line with mark
!
are criti-
cal for safety.
Replace only with part
number specified.
Note:
Les composants identifiés par
une marque
!
sont critiques
pour la sécurité.
Ne les remplacer que par une
piéce portant le numéro
spécifié.
• Refer to page 16 for Waveform.