Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6 1
1 0
Zoom operations fault
(Cannot initialize zoom lens)
Turn power off and turn power on again. When this error is
not cleared, operate the zoom lever and check following
items.
• When zooming is performed, the zoom control signal
for the lens block may be faulty.
• When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 1
3 0
Reset position detection error on the
stepper iris initializing
Turn the power on to open lens barrier. Disconnect the bat-
tery or power cord, and then connect again. And confirm
that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive cir-
cuit in lens drive block. If iris blades work normally, con-
firm that they are closing completely and confirm following
items.
• Case of the iris blades do not close normally. Replace
the lens block.
• Case of “E: 61: 30” is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
• Case of LCD is not displayed normally, check that
connection between imager board and main board.
• Case of LCD is displayed normally, replace the lens
block.
E
6 2
0 2
Abnormality of IC for steadyshot.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, replace the
board that contains this peripheral circuit.
E
6 2
1 0
Shift lens initializing failure
Replacement of lens block.
*1
If an error occurs again, steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
1 1
Shift lens overheating (PITCH)
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
E
6 2
1 2
Shift lens overheating (YAW)
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
E
6 2
2 0
Abnormality of thermistor
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, check
whether this error is due to the lens or the board. Replace
the faulty lens or board.
E
9 1
0 1
Abnormality when flash is being
charged
Checking of flash unit or replacement of flash unit.
*2
E
9 2
0 0
Battery/Dry cell distinction defect
Turn power off and turn power on again.
E
9 4
0 0
*3
Fault of writing or erasing the inter-
nal memory
Turn power off and turn power on again.
Continued
*1:
When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items. After
the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*2:
After check, be sure to perform
“1-2. Process after Fixing Flash Error”
.
*3:
Function of this code is not provided in this unit.
DSC-RX100M4
1-2
Summary of Contents for Cyber-shot DSC-RX100M4
Page 1: ...DIGITAL STILL CAMERA DSC RX100M4 SERVICE MANUAL LEVEL 2 1st Edition ...
Page 6: ......
Page 8: ......
Page 12: ......
Page 16: ......
Page 32: ......
Page 48: ......
Page 50: ...View Position Back View Front View Left View Right View Top View Bottom View DSC RX100M4 4 2 ...
Page 55: ... 2 Tilt the LCD 2 239 x 2 239 Back View 2 DSC RX100M4 4 7 ...
Page 84: ......
Page 98: ......
Page 99: ......