1-1
DSC-H20_L2
1. SERVICE NOTE
1-1. PRECAUTION ON REPLACING THE SY-224 BOARD
Restore Data
When you replace to the repairing board, get the acquire data from the former needed for the adjustment from.
Start the Adjust Manual in the Adjust Station and perform “Restore Data” to get the data.
The data getting for this model is as follows.
•
USB Serial No.
•
Angular Velocity Sensor Sensitivity Adjustment (Dp/Dy Data)
•
Wide Limit Adjustment
Note:
When you cannot read data from the former replace the same time SY-224 board and lens.
Destination Data
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “Destination Data Write”.
USB Serial No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB Serial No. Input”.
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular Velocity Sensor Sensitivity Adjustment”, input the data written down.
Note:
The sensor sensitivity of SE401 of SY-224 board is written only repair parts.
SY-224 BOARD (SIDE B)
SE401
PPP
YYY
PPP : PITCH sensor sensitivity
YYY : YAW sensor sensitivity