![Sony Cyber-shot DSC-F707 Service Manual Download Page 92](http://html.mh-extra.com/html/sony/cyber-shot-dsc-f707/cyber-shot-dsc-f707_service-manual_393196092.webp)
5-18
DSC-F707
6.
F No. Compensation
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
59 to 5D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to
“01”.
10
6
01
00
Press PAUSE button.
11
6
01
BB
Press PAUSE button.
(Note 3)
12
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 59 to 5D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2. (Refer to
page 5-13)
6
0
01
00
7.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
BC to D5
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to
“01”.
10
6
01
00
Press PAUSE button.
11
6
01
AD
Press PAUSE button.
(Note 3)
12
6
02
Check the data changes to
“01”.
13
6
AB
Check the data is “00”.
Note 3:
The adjustment data will be automatically input to page:
F, address: BC to D5.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2.
(Refer to page 5-13)
6
0
01
00