![Sony Cyber-shot DSC-F707 Service Manual Download Page 82](http://html.mh-extra.com/html/sony/cyber-shot-dsc-f707/cyber-shot-dsc-f707_service-manual_393196082.webp)
5-8
DSC-F707
1-2.
INITIALIZATION OF B, D, E, F, 7, 9 PAGE DATA
1-2-1.
Initialization of D Page Data
1.
Initializing D Page Data
Note:
If the D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of D page data
2) LCD system adjustments
Adjusting page
D
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
00
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of D
page Data”.
2.
Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camera
may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
D Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of D Page Data”)
Address
Initial value
Remark
10
00
Test mode
11 to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50 to 85
Fixed data-1 (Initialized data)
86
80
Composite video level adj.
87 to E1
Fixed data-1 (Initialized data)
E2
2D
VCO adj. (NTSC) (LCD)
E3
3C
VCO adj. (PAL) (LCD)
E4
63
V-COM adj. (LCD)
E5
56
D Range adj. (LCD)
E6
Fixed data-1 (Initialized data)
E7
6B
V-COM level adj. (LCD)
E8
90
White balance adj. (LCD)
E9
83
EA
4A
Contrast adj. (LCD)
EB to F1
Fixed data-1 (Initialized data)
F2
34
VCO adj. (NTSC) (EVF)
F3
44
VCO adj. (PAL) (EVF)
F4
Fixed data-1 (Initialized data)
F5
8E
Bright adj. (EVF)
F6, F7
Fixed data-1 (Initialized data)
F8
94
White balance adj. (EVF)
F9
82
FA
30
Contrast adj. (EVF)
FB to FF
Fixed data-1 (Initialized data)