— 12 —
CPD-4201M
2-4. PICTURE TUBE REMOVAL
1
Turn up one side of the rubber cap in
the direction indicated by arrow a .
3
When one side of the rubber cap sepa-
rates from the anode button, the anode-
cap can be removed by turning the rub-
ber cap and pulling it in the direction of
arrow c .
2
Use your thumb to pull the rubber cap
firmly in the direction indicated by
arrow b .
HOW TO HANDLE AN ANODE-CAP
REMOVAL OF THE ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
REMOVAL PROCEDURES
1
Do not use sharp objects which may cause damage to the surface
of the anode-cap.
2
Do not squeeze the rubber covering too hard to avoid damaging
the anode-cap. A material fitting called a shatter-hook terminal is
built into the rubber.
3
Do not force turn the foot of the rubber cover. This may cause the
shatter-hook terminal to protrude and damage the rubber.
Demagnetization coil
Tension spring
Stand assy
(D board)
A board
Neck assy
Deflection yoke
Four screws
(Tapping screw 5)
Anode cap
Cushion
Picture tube shield
Two screws
(BVTP 4 x 16)
1
6
9
10
5
4
3
2
7
8
a
b
Anode Button
c
Summary of Contents for CPD-4201M