CPD-110GS/110EST
A
270 mm
B
MODE
All mode
202 mm
a 2.0 mm
b 2.0 mm
a
B
A
b
B
A
A
0.30 mm
B
MODE
All mode
0.40 mm
•
Convergence Specification
•
White Balance Adjustment Specification
(1) 9300K
x = 0.283
±
0.01
y = 0.287
±
0.01
(2) 6500K
x = 0.313
±
0.01
y = 0.329
±
0.01
(3) 5000K
x = 0.346
±
0.01
y = 0.359
±
0.01
•
Vertical and Horizontal Position and Size
Specification
•
Focus adjustment
Adjustment focus (V) and focus (H) for optimum focus.
Focus (V)
FBT
3.
Receive White cross-hatch.
4.
Adjust HMC and VMC at six-pole magnet.
<6 Pole Magnet>
6
6
6
6
1
2
1
2
G
G
5.
Receive R.B. cross-hatch.
6.
Adjust XBV with four-pole magnet of DY.
7.
Repeat adjustment step from above step 1) to 6) and make
R.G.B of bote vertical and horizontal line to be overlay at
both x and y axes.
8.
Adjust H.TILT by swinging the DY neck right and left.
9.
Light tighten the lock on the magnet ass'y Neck ass'y so that
the magnet will be move easily.
10. Adjust XCV with XCV core.
XCV movement
B
R
12. Adjust Y.CLOTH with YCH VR.
YCH movement
B
R
13. Paint lock the four-pole and six-pole magnet of neck ass'y
and also four-pole magnet of DY.
<VR Adjustment on DY>
TLV
XCV
YCH
11. Adjust V.TILT with TLV VR.
TLV movement
R
B
R
B
A board
Focus (H)
4
4
1
2
4
4
1
2
B
R
1
2
R
B
B
R
1 2
+
R
B
1
2
B
R
R
B
1 2
+
1.
Receive R.B. cross-hatch.
2.
Adjust H.STAT nad V.STAT at four-pole magnet.
<4 Pole Magnet>
4-2