11
—
CPD-100ES
<Zero Position NECK Ass'y>
Purity 4-Pole Mg 6-Pole Mg
Vertical and Horizontal Position and Size
Specification
Convergence Specification
Focus adjustment
Adjust focus (V) and focus (H) for optimum focus.
10. Adjust V.TILT with TLV VR.
TLV movement
11. Adjust Y.CROSS with YCH VR.
YCH movement
12. Paint lock the four-pole and six-pole Mg.
<VR Adjustment on DY>
2
1
2
1
G
G
R
B
R
B
Less than
10 mm
R
B
Less than
10 mm
3. Receive White cross-hatch.
4. Adjust HMC and VMC at six-pole magnet.
< 6 Pole Magnet>
5. Receive R.B. cross-hatch.
6. Adjust XBV at DY four-pole magnet.
XBV Correction
a
When
1) Open DY four-pole. (Do not move H.STAT)
2) Re-adjust V.STAT with four-pole at NECK Ass'y.
b
When
1) Close DY four-pole. (Do not move H.STAT)
2) Re-adjust V.STAT with four-pole at NECK Ass'y.
7. Repeat the above procedure so that R.G.B. will on X, Y axis.
8. Adjust H.TILT by swinging the DY neck right and left.
9. Adjust XCV with XCV core.
XCV movement
R
B
B
R
R
B
DY XBV
Dot adjustment
a < 2.5mm
b < 2.5mm
A B
202 270
b
b
a
a
A
B
A 0.24mm
B 0.30mm
B
A
0.30mm
0.35mm
A-BOARD
Focus (H)
Focus (V)
FBT
YCH
TLV
XCV
R
B
B
R