– 10 –
FM VCO Adjustment
Procedure :
1. Connect the frequency counter to
4
and
7
pins of IC1 as shown
the figure below.
2. Turn the set to 98MHz.
3. Adjust RV1 for 75.95kHz – 76.05kHz reading on frequency
counter.
[TUNER BOARD] (Conductor side)
FM RF signal
generator
Carrier frequency : 90MHz
Modulation : no modulation
Output level : 65dB (1.8mV)
telescopic
antenna
terminal
set
0.01
µ
F
L4 : MW Frequency
Coverage Adjustment
CT5 :
L5 :
SW Tracking
Adjustment
CT7 : LW Tracking Adjustment
L3 : MW Tracking Adjustment
CT3 : MW Tracking Adjustment
L1 : FM Tracking Adjustment
CT1 : FM Tracking Adjustment
L6 :
SW Frequency
Coverage Adjustment
CT6 :
L8 :
CT8 :
T1 : AM IF Adjustment
L2 : FM Frequency
Coverage Adjustment
CT2 : FM Frequency
Coverage Adjustment
CT4 : MW Frequency Coverage
Adjustment
(Component side)
[TUNER BOARD]
LW Frequency
Coverage Adjustment
Adjustment Location : Tuner board
frequency counter
1
µ
F
33k
Ω
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299