8
CFM-S1
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
AM(MW/SW) IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
455kHz
MW FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L4
520kHz <516kHz>
CT4
1,680kHz <1,630kHz>
MW TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
600kHz
CT3
1,400kHz
SW1 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L7
2.2MHz
CT7
7.3MHz
SW1 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L6
2.2MHz
CT6
7.3MHz
SW2 FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L9
6.8MHz
CT9
22.5MHz
SW2 TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L8
6.8MHz
CT8
22.5MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a maximum reading on level meter.
L2
86.50MHz <87.35MHz>
CT2
109.50MHz <107.80MHz>
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
86.50MHz <87.35MHz>
CT1
109.50MHz <107.80MHz>
< > : Saudi Arabia model
[MAIN BOARD]
(Component side)
CT1 : FM Tracking Adjustment
CT3 : MW Tracking Adjustment
CT6 : SW1 Tracking Adjustment
L6 : SW1 Tracking Adjustment
L3: MW Tracking Adjustment
T1 : AM (MW/SW) IF Adjustment
L5 : FM IF Adjustment
L2 : FM Frequency
Coverage Adjustment
CT4: MW Frequency
Coverage Adjustment
CT2 : FM Frequency
Coverage Adjustment
L4 : MW Frequency
Coverage Adjustment
CT7 : SW1 Frequency
Coverage Adjustment
L7 : SW1 Frequency
Coverage Adjustment
CT8 : SW2 Tracking Adjustment
L8 : SW2 Tracking Adjustment
CT9 : SW2 Frequency
Coverage Adjustment
L9 : SW2 Frequency
Coverage Adjustment
L1 : FM Tracking Adjustment
Adjustment Location :
MAIN board (Component side)
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
L5