– 22 –
Procedure:
1. Connect the oscilloscope to TP2 (FE) and TP (VC) on BD
board.
2. Connect the TP3 (FEI: IC101 pin
@ª
) and TP (VC) with lead
wire.
3. Turned power switch on.
4. Put disc (YEDS-18) in and turned power switch on again and
actuate the focus search. (actuate the focus search when disc
table is moving in and out.)
5. Confirm that the oscilloscope waveform (S-curve) is symmetri-
cal between A and B. And confirm peak to peak level within
3.0 ± 1.0 Vp-p.
S-curve waveform
6. After check, remove the lead wire connected in step 2.
Note:
•
Try to measure several times to make sure that the ratio
of A : B or B : A is more than 10 : 7.
•
Take sweep time as long as possible and light up the
brightness to obtain best waveform.
RF Level Check
Connection:
Procedure:
1. Connect the oscilloscope to TP1 (RF) and TP (VC) on BD
board.
2. Turned power switch on. (stop mode)
3. Put disc (YEDS-18) in and press the
(
button.
4. Confirm that the oscilloscope waveform is clear and check RF
signal level is correct or not.
Note: Clear RF signal waveform means that the shape “
≈
” can
be clearly distinguished at the center of the waveform.
RF signal waveform
SECTION 5
ELECTRICAL ADJUSTMENTS
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
(with the 10: 1 probe
in use)
level: 1.2
Vp-p
+0.25
–0.20
+
–
BD board
TP2 (FE)
TP (VC)
oscilloscope
A
B
symmetry
within 3.0 ± 1.0 Vp-p
+
–
BD board
TP1 (RF)
TP (VC)
oscilloscope
(AC range)
– 21 –
Connecting Location:
[BD BOARD] (SIDE B)
IC361
TP18
(ADJ)
TP13
(XPLCK)
CN107
CN101
TP1
(RF)
TP4
(TE)
TP5
(TEI)
TP2 (FE)
TP3 (FEI)
TP (VC)
IC104
IC102
Notes:
1. CD block basically constructed to operate without adjustment.
Therefore, check each item in order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise
indicated.
3. Use the oscilloscope with more than 10 M
Ω
impedance.
4. Clean an object lens by an applicator with neutral detergent
when the signal level is low than specified value with the fol-
lowing checks.
S-Curve Check
Connection:
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
+
–
BD board
TP4 (TE)
TP (VC)
oscilloscope
(DC range)
level: 1.3 ± 0.7 Vp-p
+
–
TP13 (XPLCK)
BD board
frequency counter
A
Symmetry
B
Procedure:
1. Connect the TP18 (ADJ) to ground and TP5 (TEI: IC101 pin
@¶
) to TP (VC)with lead wire.
2. Connect the oscilloscope to TP4 (TE) and TP (VC) on BD
board.
3. Turned power switch on.
4. Put disc (YEDS-18) in and press the
(
button.
5. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to A Vdc, and check this level.
Traverse waveform
A/B
×
100 is ± 20 % or less.
6. After check, remove the lead wire connected in step 1.
RF PLL Free-run Frequency Check
Connection:
Procedure:
1. Connect the frequency counter to TP13 (XPLCK).
2. Turned power switch on.
3. Put disc (YEDS-18) in and press the
(
button.
4. Confirm that the reading on frequency counter is 4.3218 MHz.
E-F Balance (Traverse) Check
Connection:
Summary of Contents for CDP-XA30ES
Page 4: ... 4 SECTION 2 GENERAL This section is extracted from instruction manual ...
Page 5: ... 5 ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 8: ... 8 ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 ...
Page 12: ... 12 ...
Page 13: ... 13 ...
Page 14: ... 14 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......