1-2-l 1. Color Reproduction Adjustment
When adjustment is off, the color restoration will be poor.
Subject
Color bar chart standard picture frame
Measurement point
output terminal
Measuring instrument
I
Vectorscope,
Color bar chart standard picture frame
I
Adjustment page
Adjustment address
F
OA
HUE)
OB (R-Y
2F (B-Y GAIN)
32 (R-Y GAIN)
Specified value
color luminance points should settle with
in each color
frame
Note
: Make this adjustment after first performing the “Entry of Auto White Balance Reference Data”.
Adjusting method :
Set the iris to fully open and display the color bar on the reference screen.
Sequence Page
Address
Data
Procedure
Conditions
1
6
00
01
Release
the protect.
2
6
14
06
Press the PAUSE button after setting the data.
3
6
13
01
Press the PAUSE button after setting the data.
4
03
ress the PAUSE button after setting the data.
I
I
5
6
01
O F
Press the PAUSE button after setting the data.
6
F
10
Press the PAUSE button after setting the data.
7
F
63
F6
Press the PAUSE button after setting the data.
8
F
O A
Change each data, set the color restoration for each color
O B
brightness point, and press the PAUSE button for each
2F
address.
32
B-Y
Fig. B-l-8.
B - Y
Direction of the Movements of the
Adjustment Address and Luminance Point
6