1-2 (E)
CBK-SD01
1-4. Opening and Closing the Inside
Panel
Opening the Inside Panel
n
Be sure to turn off the POWER switch, unplug the AC
power cord or remove the battery before starting the
following procedure to prevent the inside of the unit from
damage.
1.
Loosen the four screws (with drop-safe) and open the
inside panel in the direction of the arrow.
m
.
Folding the flexible card wire connected to the FP-
140 board (the FP-121A board for MSW-900/900P)
shortens the life of the flexible card wire significant-
ly. Be very careful when handling the flexible card
wire not to fold it.
.
To install CBK-SD01 in MSW-900/900P, place the
unit so that the inside panel is positioned on top of
the POWER switch when the inside panel is opened.
Flexible card wires
Inside panel
FP-121A board
Inside panel
Hook
Hinge
POWER switch
Hinge
Hook
Screw
(with drop-safe)
Screw (with drop-safe)
Screws
(with drop-safe)
Flexible card wires
Inside panel
FP-140 board
Hook
Hinge
Hinge
Hook
Screw
(with drop-safe)
Screw (with drop-safe)
Screws
(with drop-safe)
PDW-510/510P/530/530P is shown.
MSW-900/900P is shown.