Internal Boards and Switch Settings

10

a

 TR-132 board

A

S1 switch

Available in near future.  Set this switch to OFF.

b

 MA-128 board

A

S1 switch

Available in near future.  Set this switch to OFF.

B

S2 switch

Set to ON only when supplying AC power to the 
microphones connected to the AUDIO IN CH 1/2 
connectors.  Normally, set this switch to OFF.

C

S3 switch

Set according to the microphone type of the headset 
connected to the INCOM 1 connector.

DYN

:  Dynamic-type microphone

CM

:  Carbon-type microphone

D

S4 switch

Set to ON when an unbalanced-type headset is connected 
to the INCOM 1 connector.

E

S5 switch

Sets the gain for the headset connected to the INCOM 1 
connector.

+

 :  Sets the gain 6 dB above the standard level.

0

 :  Standard level.

– 

:  Sets the gain 6 dB below the standard level.

Normally, set this switch to 0.

F

S6 switch

When set to ON, the audio signals input from the AUDIO 
IN CH 1/2 connectors are mixed to the imtercom audio and 
output to the INCOM 1 connector. This switch is factory-
set to OFF.

G

S7 switch

When set to ON, the audio signal input from the 
TRACKER connector is mixed to the imtercom audio and 
output to the INCOM 1 connector. Normally, set this 
switch to OFF (center position).

H

S8 switch

Specifies whether the VR of the INCOM 1 is used for 
serial mix or parallel mix. Normally, set this switch to OFF.

I

S10 switch

This switch is used for the intercom system connected to 
the INCOM 1 connector. Normally, set this switch to 
NORM.

S1

A

S1 switch

S1

S6

S8

S7

S10

S14

S13

S12

S11

A

S1 switch

I

S10 switch

J

S11/S12 switches

G

S7 switch

F

S6 switch

H

S8 switch

B

S2 switch

C

S3 switch

D

S4 switch

E

S5 switch

K

S13/S14 switches

qs

S15 switch

Summary of Contents for CA-590P

Page 1: ...sh 1st Edition Revised 1 The supplied CD ROM includes operation manuals for the CA 590 590P CCU 590 590P and CCU 790 790P English Japanese French German Italian and Spanish versions in PDF format For more details see Using the CD ROM Manual on page 5 ...

Page 2: ... with the CE marking complies with both the EMC Directive and the Low Voltage Directive issued by the Commission of the European Community Compliance with these directives implies conformity to the following European standards EN60950 1 Product Safety EN55103 1 Electromagnetic Interference Emission EN55103 2 Electromagnetic Susceptibility Immunity This product is intended for use in the following ...

Page 3: ...llez consulter les adresses indiquées dans les documents de service ou de garantie séparés Für Kunden in Europa für CA 590P Der Hersteller dieses Produkts ist Sony Corporation 1 7 1 Konan Minato ku Tokyo Japan Der autorisierte Repräsentant für EMV und Produktsicherheit ist Sony Deutschland GmbH Hedelfinger Strasse 61 70327 Stuttgart Deutschland Bei jeglichen Angelegenheiten in Bezug auf Kundendien...

Page 4: ...M 139 board 12 e MB 1019 board 12 Preparations 14 Attaching the CA 590 590P to a BVP E10 E10P E10WS E10WSP E30 E30P E30WS E30WSP Color Video Camera 14 Securing the triax cable to the camera adaptor 15 Connections 17 Connectable equipment 17 Power supply 17 Self Diagnostics 18 Displaying the DIAGNOSIS menu 18 The contents of the self diagnostics results 18 Specifications 19 General 19 Input output ...

Page 5: ...ice about choosing devices please contact your Sony dealer or a Sony sales representative Using the CD ROM Manual The supplied CD ROM includes versions of the Operation Manuals for the CA 590 590P CCU 590 590P and CCU 790 790P1 in PDF format 1 Available languages Japanese CA 590 and CCU 590 only English French German Italian and Spanish Preparations The following program must be installed on your ...

Page 6: ...os f INCOM level controls PROD ENG switches and MIC LEVEL switches h TRACKER connector i DC IN connector j RETURN connector k PROMPTER connector l DC OUT connector switch m AUDIO IN CH 1 2 connectors FRONT REAR LINE switches and MIC 48V OFF switches n REMOTE connector o RET CTRL connector x MIC switches v ENG control u TRACKER control t PGM1 2 controls s LEVEL switch p EARPHONE jack q CALL button ...

Page 7: ...ntercom microphone Turn the intercom microphone on and off using the control on the external equipment connected to the RET CTRL connector Adjust the intercom reception level with the INCOM level control OFF FRONT Turns off the intercom microphone Turn the intercom microphone on and off using the control on the external equipment connected to the RET CTRL connector or the VTR S S switch on the vid...

Page 8: ...or selecting the return video and for turning the intercom microphone on and off p EARPHONE jack mini jack Connects an earphone for monitoring the audio from the intercom or the program Select the audio source with the S251 and S252 switches on the internal AU 294 board q CALL button Use this button to call the CCU or MSU master setup unit operator When this button is pressed the red tally lamps i...

Page 9: ...lectric shock fire or injury do not open the cabinet To adjust the internal settings refer to qualified service personnel Note CA 590 590P Unscrew the four screws MD 132 board no switches a TR 132 board b MA 128 board c AU 294 board CA 590 590P Unscrew the four screws d DM 139 board e MB 1019 board ...

Page 10: ...evel Sets the gain 6 dB below the standard level Normally set this switch to 0 F S6 switch When set to ON the audio signals input from the AUDIO IN CH 1 2 connectors are mixed to the imtercom audio and output to the INCOM 1 connector This switch is factory set to OFF G S7 switch When set to ON the audio signal input from the TRACKER connector is mixed to the imtercom audio and output to the INCOM ...

Page 11: ... signal input from the TRACKER connector is mixed to the imtercom audio and output to the INCOM 2 connector Normally set this switch to OFF center position E S8 switch Specifies whether the VR of the INCOM 2 is used for serial mix or parallel mix Normally set this switch to OFF F S10 switch This switch is used for the intercom system connected to the INCOM 2 connector Normally set this switch to N...

Page 12: ... connector factory setting REM Available in near future TX The video signal input to the PROMPTER connector is output to the CCU Note that the CCU 550D 550DP does not support this function B S302 switch Selects the signal to be output from the PROMPTER connector PROMPT Prompter video signal is output factory setting RET Return video signal is output e MB 1019 board S11 4 Program audio 2 OFF S12 Tr...

Page 13: ...Return video signal is output factory setting MONI Monitor video signal is output VBS Composite video signal is output B S2 switch Selects the signal to be input output from the PROMPTER connector PROMPT Prompter video signal is input and output factory setting REF Reference signal for the video camera is input ...

Page 14: ...lor Video Camera as shown below the 68 pin connectors on both units are automatically connected 1 Attach the CA 590 590P to the rear of the color video camera Hook the upper part then push the lower part in until it snaps into place 2 Tighten the screw with a coin Removing a Camera Adaptor Loosen the screw on the video camera until it stops then remove the camera adaptor while pushing the screw Ti...

Page 15: ...tach the supplied cable holder with the supplied two M3 6 screws 2 Route the triax cable as illustrated below then fasten the cable holder around the cable Loosen the screw on the video camera until it stops then push it M3 6 screws supplied Cable holder supplied cable ...

Page 16: ...16 Preparations Removing the cable from the cable holder Pull Lift to release ...

Page 17: ...the DC connector Set the POWER swicth to EXT CCU 700A 700AP 790 790P Camera Control Unit BVF 55 55CE 5 inch Viewfinder To the CAMERA connector CCU 550D 550DP 590 590P Camera Control Unit To the triax connector Triax cable RM B750 Remote Control Unit RCP 750 751 920 921 Remote Control Panel Camera cable To the REMOTE connector To the DC IN connector AC DN10 AC Adaptor To the DC OUT connector DC cor...

Page 18: ...al MD board AU Status of the internal AU board TR Status of the internal TR board When an abnormality is detected NG appears for the corresponding internal board When an abnormality is detected on the fan of the CA power unit and NG alternate on all the internal board status indications And when NG appears on all the internal board status indications an abnormality may have occurred on the CA powe...

Page 19: ...pin When a 5 inch viewfinder is connected to this unit or the TRACKER connector or the REMOTE connector is used the maximum 1 5 A DC output cannot be obtained from the DC OUT connector Supplied accessories Carrying belt 1 Cable holder 2 M3 6 screws 4 Operation Manual 1 CD ROM 1 Optional accessories CAC 6 Return Video Selector BVF 55 55CE Viewfinder RM B750 Remote Control Unit Design and specificat...

Page 20: ......

Page 21: ... for use by the purchasers of the equipment described in this manual Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation ...

Page 22: ...CA 590 590P UC CE 3 869 644 02 1 Printed in Belgium 2007 04 08 2005 Sony Corporation ...

Reviews: