SELF DIAGNOSIS FUNCTION
[SELF DIAGNOSTIC SCREEN DISPLAY]
• Panel Operation Time is recorded every 30 min,
but Total Operation Time is recorded every 1 hr .
Therefore, the panel op. time might become larger than the total op. time.
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
Since the diagnostic results displayed on the screen are not automatically cleared,
always check the self-diagnostic screen. After you have completed the repairs, clear the result display to “0”.
Clearing the Self Check Diagnostic List
Panel operation time :
Press the Channel 7 => Channel 0 .
To exit the Self Diagnostic screen...
*If you want to finish service mode app, do AC OFF/ON
→Service mode app is disable perfectly
*if you want to move home menu, push <HOME> button
→Service mode app do background(not disable perfectly)
NOTE:
This model does not have the function to clear the error history of self-diagnostic screen
by the operation of “press the Channel 8 => Channel 0”.
SELF CHECK
<<
002 MAIN_POWER 000000000000 000000000000 000000000000 000
003 DC_ALERT 000000000000 000000000000 000000000000 000
003 AUD_ERR 150101000018 150101000018 150101000018 003
003 HDMI_EQ 150101000123 150101000045 150101000045 003
003 TU_DEMOD 150101000218 150101000223 150101000105 003
004 LD_ERR 000000000000 000000000000 000000000000 000
004 BCM_ERR 000000000000 000000000000 000000000000 000
005 TCON_ERR 150101000504 000000000000 000000000000 001
005 P_ID_ERR 000000000000 000000000000 000000000000 000
006 BACKLIGHT ERR 000000000000 000000000000 000000000000 000
007 TEMP_ERR 150101000200 150101000002 000000000000 002
007 4KBE_ERR 000000000000 000000000000 000000000000 000
008 SW_ERR 000000000000 000000000000 000000000000 000
Back
00005 00414 00002
[Home]Exit
Smart Core Red LED
blinking count
Error Naming
Error count
Total Operation Time [hr]
– Boot Count – Panel Operation Time [hr]
Error
timestamp for
last recorded
error
Error
timestamp for
second last
recorded error
Error
timestamp for
3rd last
recorded error
" These items are
disabled."
For errors with symptoms such as “power sometimes shuts off” or
“screen sometimes goes out” that cannot be confirmed,
it is possible to bring up past occurrences of failure for confirmation on the screen:
In standby mode, press buttons on the remote commander sequentially in rapid
succession as shown below:
Summary of Contents for BRAVIA XBR-55X930D
Page 61: ...XBR 55 65X930D 65X935D 937D 75X940D 61 DIAGRAMS BLOCK DIAGRAM Common for all inches ...
Page 85: ...XBR 55 65X930D 65X935D 937D 75X940D 85 DISASSEMBLY 1 6 CATCHER 1 XBR 55X930D CATCHER ...
Page 93: ...XBR 55 65X930D 65X935D 937D 75X940D 93 DISASSEMBLY 1 14 WIRE DRESSING 1 XBR 55X930D ...
Page 187: ...XBR 55 65X930D 65X935D 937D 75X940D 187 DISASSEMBLY 4 19 WIRE DRESSING 4 XBR 75X940D 1 2 ...
Page 193: ...XBR 55 65X930D 65X935D 937D 75X940D 193 DISASSEMBLY 4 25 WIRE DRESSING 4 XBR 75X940D NOTE ...
Page 195: ...XBR 55 65X930D 65X935D 937D 75X940D 195 DISASSEMBLY 4 27 WIRE DRESSING 4 XBR 75X940D 1 2 ...
Page 215: ...XBR 55 65X930D 65X935D 937D 75X940D 215 DISASSEMBLY 4 XBR 75X940D 4 47 LCD PANEL LCD PANEL ...