- 34 -
KDS-70R2000
RM-ED006
The user settings can be reset to the factory default condition as
follows.
1. Press “TEST “ and “RESET “ key in sequence when the set
is ON.
The LAMP,TIMER and POWER LED light and the picture
is muted.
After about 5 seconds the LAMP and TIMER LED go off,
and the color of POWER LED changes from amber to
green.
After another 10 seconds the reset is completed and the
initial set-up display appears.
4-4. H/V CENTER CONFIRMATION AND
ADJUSTMENT
Please check the picture horizontal/vertical center after the
replacement of the following parts .
• Optical block
• Top assembly
1.
Check H/V center with 480i monoscope signal in “Full “
mode.
2.
If the center is shifted , adjust it with the following service
items .
Please record the steps shifted as
DFD 16
and
CXD9713 .
4-3. TEST RESET
DEM/TG H_CENT (for H center)
V_CENT (for V center)
V_SENT
H_CENT
Commander Function
Button
Mode
Description
[MUTING]
+
[ENTER]
WRITE
Writes data to NVM.
-
+
[ENTER]
READ
Reads data from NVM.
FUNCTION OF KEYS ON COMMANDER
•
1
: Changes adjustment item. (item No. moves up)
•
4
: Changes adjustment item. (item No. moves down)
•
2
: Changes adjustment category.
(category moves up)
•
5
: Changes adjustment category.
(category moves down)
•
3
: Changes data value. (up)
•
6
: Changes data value. (down)
4-2-3. Memory Write Confirmation Method
1. After adjustment, turn power off with the remote commander.
2. Turn power on and set to service mode.
3. Call the adjusted items again and confirm they were adjusted.
4-2-4. Adjusting Buttons and Indicator
POWER
DISPLAY
MUTING
ENTER
VOL +
Adjustment item
u p
Adjustment item
down
Initialise data
(Not stored)
Adjustment category
u p
Data up
Data down
Adjustment category
down
Read data from
NVM