Service Procedure for Panel, Board and Software Change / Upgrade(WW)
43
1-2. Procedure to Set HOTEL RS232C Protocol
APPENDIX 2
1. Access Service Mode by pressing the buttons when TV in Standby.
“DISPLAY
Æ
5ch
Æ
Vol+
Æ
POWER” on the remote commander.
2. Select [002 MODEL – 004 SHIP_CONFIRM]
Press “1” button on the remote commander several times.
3. Enter to SHIP_CONFIRM
Press “0” button on the remote commander.
Example
DIGITAL
SERVICE
001
OP
000
VERS
‐‐‐
<MAIN>
<EXT>
DM1.301JPA
RF:01.05
WF1.003W00AA
WF:2.0.0.99
DF1.001W00AA
WF:0B
YM1.010W00AA
CAM:X.XXX
DB2.105W00AA
FD:XXXX
(DM1.301W00AA)
DD1.016W00AA
WP0.521W00AA
<PEM>
MID:1C117081
PM1.012W00LU
PID:04020000
PB1.000W00LU
PNL:
PL1.011J46LUX
FDMR370NN0101
PD1.011J46LUX
TUNER
:ENABLE
DIGITAL
SERVICE
002
MODEL
004
SHIP_CONFIRM
‐‐‐
DIGITAL
(MODEL)
SERVICE
Confirmation
for
Shipping
4. Enter to Product Code Input Menu
Press “+”(Select) button on the remote commander.
DIGITAL
(MODEL)
SERVICE
Confirmation
for
Shipping
Current
ProductCode
P________
Please
input
8
digit
ProductCode
(00000000
‐
99999999)
P________