SAFETY CHECK-OUT
Leakage Test
The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed
metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’
instructions to use these instructions.
2. A battery-operated AC milliampmeter. The Data Precision 245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The
“limit” indication is 0.75 V, so analog meters must have an accurate low voltage scale.
The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all
battery-operated digital multimeters that have a 2 VAC range are suitable (see Figure A).
How to Find a Good Earth Ground
A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also
at earth ground.
If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance
between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms.
If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- light (not a neon lamp) between the hot
side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the
lamp should light at normal brilliance if the screw is at ground potential (see Figure B).
Summary of Contents for BRAVIA KDL-32R500C
Page 2: ...SERVICE MANUAL LCD TV GN1S CHASSIS Segment SE2N 9 888 173 A1 ...
Page 97: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 97 DIAGRAMS 4 2 CONNECTOR DIAGRAM 4 2 1 BA i ...
Page 98: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 98 DIAGRAMS 4 2 2 BA ii ...
Page 99: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 99 DIAGRAMS 4 2 3 BA with K Board i ...
Page 100: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 100 DIAGRAMS 4 2 4 BA with K Board ii ...
Page 101: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 101 DIAGRAMS 4 2 5 BA Hotel i ...
Page 102: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 102 DIAGRAMS 4 2 6 BA Hotel ii ...
Page 106: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 106 DIAGRAMS 4 4 3 Tape 1 Wire Dressing 106 ...
Page 110: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 110 DIAGRAMS 4 4 7 Tape 3 Wire Dressing 110 ...
Page 111: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 111 DIAGRAMS 4 4 8 Tape 4 Wire Dressing 111 ...
Page 112: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 112 DIAGRAMS 4 4 9 Tape 5 Wire Dressing 112 ...
Page 119: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 119 DIAGRAMS 4 4 16 Hook Wire Dressing 119 ...
Page 120: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 120 DIAGRAMS 4 4 17 Tape 6 Wire Dressing 120 ...
Page 121: ...KDL 32R500C 505C 507C 40 48R510C 550C 555C 557C 121 DIAGRAMS 4 4 18 Tape 7 Wire Dressing 121 ...